8
-
Item
Model
SCM80ZF-S
Cooling capacity
W
8000 (1000~9300)
Heating capacity
W
9300 (950~9500)
Power source
1 Phase 220/230/240V 50Hz
Power consumption
Cooling
W
2380 (280~3200)
Heating
2430 (250~3500)
Running current
Cooling
10.9/10.5/10.0
Heating
A
11.2/10.7/10.2
Sound level
Cooling : 51 Heating : 52
Noise level
Power level
dB
Cooling : 65 Heating : 66
Exterior dimensions
Height
×
Width
×
Depth
mm
750
×
880
×
340
Color
Stucco white
Net weight
kg
66
Refrigerant equipment
Compressor type & Q’ty
[Twin rotary]
×
1
Motor
kW
1.3
Starting method
Direct start
Refrigerant control
Capillary tubes
+
Electronic expansion valve
Refrigerant
kg
R410A 3.15 (Pre-charged up to the piping length of 40m)
Refrigerant oil
R
0.67 (MEL56)
Air handling equipment
Fan type & Q’ty
Propeller fan
×
1
Motor
W
86
Air flow (at high)
CMM
55
Shock & vibration absorber
Rubber (for compressor)
Safety equipment
Size
×
Core
×
Number
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
×
4
Gas line:
φ
9.52 (3/8
″
)
×
4
Connecting method
Flare connecting
Attached length piping
—
Insulation
Necessary (Both Liquid & Gas lines)
Power source supply
Terminal block (Screw fixing type)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
×
4
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Union : (
φ
9.52
/
φ
12.7)
×
2
Installation sheet, Manual instruction
SKM20, 22, 25, 28, 35, 50 type
Indoor unit to be combined
STM25, 35, 50, 60 type
SRRM25, 35, 50, 60 type
Compressor overheat protection, Overcurrent protection
Serial signal error protection
Refrigerant
piping
Connection
wiring
Model SCM80ZF-S
Notes (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27
°
C
19
°
C
35
°
C
24
°
C
ISO-T1, JIS C9612
Heating
20
°
C
–
7
°
C
6
°
C
ISO-T1, JIS C9612
(2) The values for capacity and power consumption shown in a range ( ) indicate the minimum and maximum of the range.
(3) If the piping length exceeds 40 m, additional charging is required. (20g/m)
Summary of Contents for SRRM25ZF-S
Page 126: ...MEMO ...