'16 • SRK-T-192
Model
Item
SRK18YLV-S1
Indoor unit
SRK18YLV-S1
Outdoor unit
SRC18YLV-S1
Cooling capacity (1)
W
5000 (1600 (Min.)~5500 (Max.))
Power source
1 Phase, 220-240V, 50Hz
Operation
data
Power
consumption
Cooling
kW
1.56 (0.40~2.20)
Running
current
Cooling
A
7.5
Inrush current
7.5
COP
Cooling
3.21
Noise
level
Cooling
Sound level
dB(A)
Hi : 49 Me : 37 Lo : 28
55
Power level
dB
63
67
Exterior dimensions (Height x Width x Depth)
mm
268 x 790 x 213
595 x 780 (+62) x 290
Exterior appearance
(Munsell color)
Fine snow
(8.0Y 9.3/0.1) near equivalent
Stucco white
(4.2Y 7.5/1.1) near equivalent
Net weight
kg
9.5
35
Refrigerant
equipment
Compressor type & Q'ty
—
5RS132XAB21 (Rotary type) x 1
Motor (Starting method)
kW
—
1.50 (Line starting)
Refrigerant oil
0.37 (FV50S)
Refrigerant (4)
kg
R410A 1.30 (Pre-charged up to the piping length of 15m)
Heat exchanger
Slit fins & inner grooved tubing
M fins & inner grooved tubing
Refrigerant control
Capillary tubes + Electronic expansion valve
Deice control
Microcomputer control
Air handling
equipment
Fan type & Q'ty
Tangential fan x 1
Propeller fan x 1
Motor
W
38
24
Air flow
Cooling
m
3
/ min
Hi : 12.0 Me : 7.6 Lo : 4.7
38
Fresh air intake
Not possible
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 2
—
Shock & vibration absorber
—
Cushion rubber (for compressor)
Operation
control
Operation switch
Wireless remote control
—
Room temperature control
Microcomputer thermostat
—
Operation Display
RUN : Green, TIMER : Yellow, HI POWER : Green,
3D AUTO : Green
Safety devices
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Fan motor error protection,
Cooling overload protection, Lock rotor protection
Installation
data
Refrigerant piping size (O.D)
mm
Liquid line :
φ
6.35 (1/4") Gas line :
φ
12.7 (1/2")
Connecting method
Flare connecting
Attached length of piping
m
Liquid line : 0.4
Gas line : 0.33
—
Insulation for piping
Necessary (Both sides), independent
Refrigerant line (one way) length
m
Max. 25
Vertical height difference between
outdoor unit and indoor unit
Max. 15 (Outdoor unit is higher)
Max. 15 (Outdoor unit is lower)
Drain hose
Connectable (VP 16)
—
Recommended breaker size
A
16
Connection wiring
Size x Core number
1.5mm
2
x 4 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Option parts
—
Adapted to
RoHS
directive
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO-T1 , JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
The pipe length is 7.5m.
1. SPECIFICATIONS
Summary of Contents for SRK18YLV-S1
Page 2: ......
Page 3: ...TECHNICAL MANUAL ...
Page 9: ... 16 SRK T 192 3 Wireless remote control Unit mm 60 17 3 150 ...
Page 53: ... 50 16 SRK T 192 ...
Page 54: ... 51 16 SRK T 192 PARTS LIST INDOOR UNIT SRK18YLV S1 OUTDOOR UNIT SRC18YLV S1 ...
Page 59: ... 56 16 SRK T 192 CRBE0294 6 13 11 18 12 15 16 3 17 14 2 4 9 8 7 5 1 8 8 10 PANEL FAN ASSY ...