−29−
Setting of HW temp for the operation to top up
The HW temp for the operation to top up can be set as follows.
1.
Tap the HW temp button on the HW TOP screen.
2.
The menu screen of the [Setting of HW temp] is displayed.
Tap the desired item.
①
Setting temp to top up
②
Setting temp to warm up (Out of use)
3.
If the multiple heat pump units is connected to the
remote control, the list of heat pump units (Address No.)
is displayed.
Tap the [HP unit No.] to be set.
Up to 8 units is displayed on the [Select heat pump unit]
screen. If 9 or more units are connected, the 9th and the
subsequent units are displayed by tapping Next button.
4.
Set the HW temp by tapping
▲ ▼
buttons and tap
Set button.
5.
The TOP screen is displayed, when tapping Set button
■
The HW temp can be set at 5°C intervals.
HW temp setting range: From 60 to 90°C (Factory default: 65°C)
■
If tapping Back button without tapping Set button, the setting
becomes invalid and it returns to the HW TOP screen.
■
The [Admin password input] screen may be displayed according to
the setting of [Enable/Disable setting] (
☞
Page 59)
· If the “Unvented cylinder” is connected, the HW temp for the operation to warm up can not be set.
· Actual HW outlet temp may differ about ±3°
C
from the set HW temp by the operating conditions.
Information
1
2
Summary of Contents for ESA30EH2 Series
Page 2: ... 2 ...
Page 85: ... 83 MEMO ...