![Mitsubishi Electronic FR-E860 Series Instruction Manual Download Page 46](http://html.mh-extra.com/html/mitsubishi-electronic/fr-e860-series/fr-e860-series_instruction-manual_1811926046.webp)
45
2. Installation and Wiring
2.6 Control circuit
1
2
3
4
5
6
7
8
9
10
• Phoenix Contact Co., Ltd.
• NICHIFU Co., Ltd.
NOTE
• When using stranded wires without a blade terminal, twist enough to avoid short circuit with a nearby terminals or wires.
• Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause an inverter damage
or injury.
Wire removal
Pull the wire while pushing the open/close button all the way down firmly with a flathead screwdriver.
Wire gauge
(mm
2
)
Ferrule part No.
Crimping tool
model No.
With insulation sleeve
Without insulation
sleeve
0.3
AI 0,34-10TQ
—
CRIMPFOX 6
0.5
AI 0,5-10WH
—
0.75
AI 0,75-10GY
A 0,75-10
1
AI 1-10RD
A 1-10
1.25, 1.5
AI 1, 5-10BK
A 1, 5-10
0.75 (two-wire
product)
AI-TWIN 2×0,75-10GY
—
Wire gauge
(mm
2
)
Blade terminal part
No.
Insulation cap part No.
Crimping tool model
No.
0.3 to 0.75
BT 0.75-11
VC 0.75
NH 69
3.
Insert the wire into the terminal block.
When using single wire or stranded wire without crimp terminal,
push an open/close button all the way down with a flathead
screw driver, and insert the wire.
Flathead screwdriver
Open/close button
Flathead screwdriver
Open/close button