─ 4 ─
3. Names and functions of components
- For L-type (for example, VL-350CZPVU-L-E),
filters, controller, and name plate are on the
reflected positions.
* The figure shows VL-350CZPVU-R-E.
1
8
2
9
3
10
5
11
6
7
Optional filter
Filter name
MODEL
Applicable model
Location to use
Main material
Replacement intervals
Replacement filter
P-250F-E
VL-250CZPVU series
RA, OA
L-Type
R-Type
RA: Return Air
OA: Outdoor Air
SA: Supply Air
PET,
acrylic fiber
Three years
P-350F-E
VL-350CZPVU series
P-500F-E
VL-500CZPVU series
Standard filter
P-250SF-E
VL-250CZPVU series
RA, OA, SA
Polypropylene,
polyester
One year
P-350SF-E
VL-350CZPVU series
P-500SF-E
VL-500CZPVU series
Medium efficiency
filter
P-250MF-E
VL-250CZPVU series
RA, OA, SA
One year
P-350MF-E
VL-350CZPVU series
P-500MF-E
VL-500CZPVU series
PM2.5 filter
P-250PF-E
VL-250CZPVU series
RA, OA, SA
For SA installation:
One year
For OA and RA installations:
Six months
P-350PF-E
VL-350CZPVU series
P-500PF-E
VL-500CZPVU series
PM1 filter
P-250PFH-E VL-250CZPVU series
RA, OA, SA
P-350PFH-E VL-350CZPVU series
P-500PFH-E VL-500CZPVU series
NOx filter
P-250NF-E
VL-250CZPVU series
SA
Pulp
Six months
P-350NF-E
VL-350CZPVU series
P-500NF-E
VL-500CZPVU series
* When a NOx filter and an optional dust catch filter (P-250/350/500SF-E, P-250/350/500MF-E, P-250/350/500PF-E,
P-250/350/500PFH-E) are used together, be sure to install a NOx filter on the SA side and a dust catch filter on the OA side.
* Install any of the filters other than NOx filter on the OA and RA side to protect the product.
4
OA
SA
RA
RA
SA
OA
2. Changed points
New model
Previous model
Changes from the previous model
VL-250CZPVU-L-ERT VL-250CZPVU-L-E To meet certification requirements of the destination countries,
Instruction Manual and Installation Manual are provided in the
local languages: Russian, Kazakh, Armenian, and Ukrainian.
The structure and characteristic values of the product are not
changed.
VL-250CZPVU-R-ERT VL-250CZPVU-R-E
VL-350CZPVU-L-ERT VL-350CZPVU-L-E
VL-350CZPVU-R-ERT VL-350CZPVU-R-E
VL-500CZPVU-L-ERT VL-500CZPVU-L-E
VL-500CZPVU-R-ERT VL-500CZPVU-R-E
No.
Name
Function
1 Exhaust air
filter
It prevents the heat exchanger
from clogging.
2 Exhaust air
filter case
It holds the exhaust air filter.
3 Optional air
filter case
For the optional filter
(See the table below.)
4 Filter cover
-
5 Drain pipe
attachment
It is connected to the drain pipe.
6 Control box
It holds the circuit board.
7 Name plate
It shows product name and serial No.
8 Outdoor air
filter
It removes insects, pollen, dirt, dust,
and other particles from the outdoor
air that is taken into the room.
9 Outdoor air
filter case
It holds the outdoor air filter.
10 Heat exchanger
(Lossnay core)
It exchanges heat between the
supply air and the return air.
11 Controller
Product operation
* The controller can be installed externally.
(Use the optional component P-RCC-E for
external installation)