104
2. Removing the inverter assembly, inverter P.C. board
and power P.C. board
(1) Remove the top panel, cabinet and service panel.
(Refer to 1.)
(2) Disconnect the power supply and indoor/outdoor
connecting wire and remove the back panel. (Refer to 1.)
(3) Disconnect the ground wires(See Photo 3.), the lead wire
to the reactor and the following connectors;
<Power P.C. board>
CN721 (4-way valve)
CN722 (Defrost heater) SUZ-KA25/KA35VAH
<Inverter P.C. board>
CN931,CN932 (Fan motor)
CN641 (Defrost thermistor and discharge temperature
thermistor)
CN643 (Ambient temperature thermistor)
CN724
(LEV)
(4) Remove the compressor connector (CN61).
(5) Remove the screws fixing the relay panel. (See Photo 3.)
(6) Remove the inverter assembly. (See Photo 3.)
(7) Disconnect all connectors and lead wires on the inverter P.C.
board. (See Photo 4.)
(8) Remove the inverter P.C. board from the inverter assembly.
(9) Remove the screw fixing the power P.C. board. (See Photo
4.)
(10) Disconnect all connectors and lead wires on the power P.C.
board.
(11) Remove the power P.C. board from the inverter assembly.
4. Removing the discharge temperature thermistor and
defrost thermistor
(1) Remove the top panel, cabinet and service panel.
(Refer to 1.)
(2) Disconnect the power supply and indoor/outdoor connecting
wire and remove the back panel. (Refer to 1.)
(3) Remove the inverter assembly. (Refer to 2.)
(4) Pull out the discharge temperature thermistor from its
holder. (See Photo 5.)
(5) Pull out the defrost thermistor from its holder. (See Photo 6.)
Photo 5
Discharge temperature thermistor
R.V. coil
OPERATING PROCEDURE
PHOTOS
Photo 3
Photo 4
Screw of the
power P.C. board
Heat sink
3. Removing R.V. coil
(1) Remove the top panel, cabinet and service panel.
(Refer to 1.)
(2) Disconnect the power supply and indoor/outdoor
connecting wire and remove the back panel. (Refer to 1.)
(3) Remove the inverter assembly. (Refer to 2.)
(4) Remove the R.V. coil. (See Photo 5.)
Inverter
P.C. board
Power
P.C. board
Screws of
the ground
wires
Screws of the
relay panel