3
3.4 Buffer Memory
3.4.9 Offset/gain range setting (Un\G25)
3
- 32
1
OV
E
R
VI
EW
2
SYSTE
M
CO
N
F
IG
UR
A
T
IO
N
3
S
P
E
CI
F
ICA
T
IO
N
S
4
SE
T
U
P
AN
D
PR
OCE
D
U
R
ES
B
E
FOR
E
OP
ER
A
T
ION
5
UT
ILI
T
Y
P
ACK
AGE
(G
X CO
NFI
G
U
R
A
T
O
R
-
DA
)
6
PROGRAMMING
7
ON
LI
N
E M
O
D
U
LE
CHANGE
8
T
R
OU
B
LES
H
O
O
T
IN
G
3.4.9
Offset/gain range setting (Un\G25)
(1) This area is used to change the output range in the offset/gain setting mode. Turning
on Channel change request (YB) changes the output range into the set one.
If any value outside the setting range is set, an error occurs and the corresponding
Error code (Un\G19) is stored.
(2) Channel change request (YB) must be turned on/off to validate the offset/gain range
setting. (Refer to Section 3.3.2.)
(3) Refer to Section 4.6 for details of offset/gain setting.
3.4.10 Rate control enable/disable setting (Un\G46)
(1) Set whether to enable or disable the rate control on each channel.
(2) To validate the settings, on/off of Operating condition setting request (Y9) is required.
(Refer to Section 3.3.2.)
(3) The default setting is all-channel rate control disable.
(4) Refer to Section 3.2.4 for details of rate control function.
3.4.11 Warning output setting (Un\G47)
(1) Set whether to enable or disable the warning output on each channel.
(2) To validate the settings, on/off of Operating condition setting request (Y9) is required.
(Refer to Section 3.3.2.)
(3) The default setting is all-channel warning output disable.
(4) Refer to Section 3.2.3 for details of warning output function.
Output range
Set value
User range setting 1
000F
H
User range setting 2
000E
H
User range setting 3
000D
H
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
CH
2
CH
1
CH
4
CH
3
CH
6
CH
5
1: Rate control disable
0: Rate control enable
Un\G46
0
0
0
0
0
0
0
b6 to b15 information is fixed at 0
0
0
0
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
CH
2
CH
1
CH
4
CH
3
CH
6
CH
5
1: Warning output disable
0: Warning output enable
Un\G47
0
0
0
0
0
0
0
0
0
0
b6 to b15 information is fixed at 0
Summary of Contents for Q66DA-G
Page 2: ......
Page 6: ...A 4 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...