16
T
otal
Electrical circuit
Refrigerant circuit
Indoor side
Outdoor
side
Representative matching
SHF
BF
W
kW
Mode
Capacity
Input
PLA-ZM71EA
PLA-ZM71EA
Cooling
7,100
1.65
Heating
8,000
1.82
6.70
2.72
1.03
77
45
13
5
27
19
14.5
35
24
0.82
0.10
7.46
2.32
0.70
81
39
4
5
20
15
35.9
7
6
—
—
1 , 50
230
PUZ-ZM71VHA
1 , 50
230
Phase , Hz
Voltage
Current
Outdoor unit
Phase , Hz
Voltage
Current
Discharge pressure
Suction pressure
Discharge temperature
Condensing temperature
Suction temperature
Ref. pipe length
Intake air temperature
Discharge air temperature
Intake air temperature
V
A
V
A
MPaG
MPaG
°C
°C
°C
m
°C
°C
°C
°C
°C
Indoor unit
D.B.
W.B.
D.B.
D.B.
W.B.
PLA-ZM35EA
PLA-ZM50EA
PLA-ZM60EA
PLA-ZM35EA
PLA-ZM50EA
PLA-ZM60EA
Cooling
3,600
0.71
Heating
4,100
0.82
Cooling
5,000
1.11
Heating
6,000
1.36
Cooling
6,100
1.45
Heating
7,000
1.71
3.17
2.51
1.12
65
42
15
5
27
19
17.5
35
24
0.97
0.18
3.53
2.04
0.74
72
34
9
5
20
15
30.8
7
6
—
—
4.80
2.68
1.02
76
44
13
5
27
19
15.5
35
24
0.81
0.17
5.85
2.44
0.69
87
41
6
5
20
15
35.5
7
6
—
—
5.66
2.62
1.00
79
44
15
5
27
19
13.4
35
24
0.73
0.13
6.77
2.54
0.72
85
43
4
5
20
15
38.9
7
6
—
—
1 , 50
230
PUZ-ZM35VKA
1 , 50
230
1 , 50
230
PUZ-ZM50VKA
1 , 50
230
1 , 50
230
PUZ-ZM60VHA
1 , 50
230
0.21
0.19
0.22
0.20
0.22
0.20
0.34
0.32
5-4. STANDARD OPERATION DATA
The unit of pressure has been changed to MPaG based on international SI system.
The conversion factor is : 1(MPaG)=10.2(kgf/cm²)
OCH653