17
6
OUTLINES AND DIMENSIONS
PUZ-ZM35VKA PUZ-ZM50VKA
Unit: mm (inch)
{
42 drain hole
251.5
404.5
Side Air
Intake
Handle for moving
63
809
310
320
8.5
630
22.3
Installation bolt pitch
Air discharge
Rear Air
intake
Side Air
intake
oval hole
2-10×21
2-U Shaped notched holes
(Foundation Bolt M10)
(Foundation Bolt M10)
500
154.5
40
330
300
360
32.5
Service port
FLARE
{
12.7 (1/2F)
Connection for
gas pipe
Connection for
liquid pipe FLARE
{
6.35 (1/4F)
Service panel for charge plug
Service panel
Earth terminal
Terminal connection
164.5
99.5
23.2
497.7
193.5
43°
35°
<Foundation bolt height>
FOUNDA
TION
Less than
Please secure the unit firmly
with 4 foundation (M10) bolts.
(Bolts, washers and nut must
be purchased locally).
FOUNDA
TION BOL
TS
Piping and wiring connection can
be made from the rear direction only
.
PIPING-WIRING DIRECTION
18mm
350mm or more
Basically open
100mm or more
100mm or more
500mm or more
2 sides should be open in
the right, left and rear side.
100mm or more as long as
no obstacle is placed on the
rear and right-and-left sides
of the unit.
Free space around the outdoor unit
(basic example)
Rear Air
Intake
OCH653