- 39 -
7-6. How to remove the XY cover
When remove the XY cover (No.1) by maintenance, please refer to the following procedures.
NOTICE For the safety, please operate more than one person.
(1) Remove the each one of the screw (No.2) and (No.3) from machine right side.
(2) Remove the two of the screws (No.2) from machine left side.
(3) Lift up the XY cover (No.1) up to the bottom of machine arm and move in the arrow direction. XY cover
(No.1) can be removed. Please operate more than one person and pay attention to XY table and
flexible tube.
<2>
<3>
<1>
<1>
<2>
<1>
<1>
<4>
<5>
<1>: XY cover <2>: Screw <3>: Screw <4>: Machine arm <5>: Flexible tube