2. Installation location
3. Installing the indoor unit
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories.
PART NUMBER
ACCESSORY
QUANTITY
LOCATION OF
SETTING
60, 71, 100
1
Mount board
1
Fix at the back of the
unit
2
Tapping screw 4
×
25
7
3
Felt tape
2
4
L-shaped connection pipe
1
5
Charge nut
1
6
Wireless remote controller
1
7
Remote controller holder
1
8
Alkali batteries (size AAA)
2
9
Tapping screw 3.5
×
16
2
0
Spacer
1
Make use of
packaging material
3.2. Installing the wall mounting fixture (Fig. 3-2)
3.2.1. Setting the wall mounting fixture and piping positions
►
Using the wall mounting fixture, determine the unit’s installation position
and the locations of the piping holes to be drilled.
Warning:
Before drilling a hole in the wall, you must consult the building contractor.
PKA-RP60, 71, 100KAL
A
Mount board
1
B
Indoor unit
C
Bottom left rear pipe hole (ø75-ø80)
D
Bottom right rear pipe hole (ø75-ø80)
E
Knockout hole for left rear hole (75 × 480)
F
Bolt hole (4-ø9 hole)
G
Center measurement hole (ø2.5 hole)
H
Tapping hole (75-ø5.1 hole)
I
Hole centre
J
Align the scale with the line.
K
Insert scale.
3.2.2. Drilling the piping hole (Fig. 3-3)
►
Use a core drill to make a hole of 75-80 mm diameter in the wall in the
piping direction, at the position shown in the diagram to the left.
►
The hole should incline so that the outside opening is lower than the
inside opening.
►
Insert a sleeve (with a 75 mm diameter and purchased locally) through the
hole.
Note:
The purpose of the hole’s inclination is to promote drain flow.
Fig. 2-1
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
Select a proper position allowing the following clearances for installation and
maintenance.
PKA-RP60, 71, 100KAL
(mm)
A
B
C
D
E
Min. 100.5
Min. 52.3
Min. 48
Min. 250
Min. 220
F
Air outlet: Do not place an obstacle within 1500 mm of the air outlet.
G
Floor surface
H
Furnishing
I
When the projection dimension of a curtain rail or the like from the wall exceeds 60 mm,
extra distance should be taken because the fan air current may create a short cycle.
J
1800 mm or greater from the floor surface (for high location mounting)
K
108 mm or greater with left or rear left piping and optional drain pump installation
L
550 mm or greater with optional drain pump installation
M
Minimum 7 mm: 265 mm or greater with optional drain pump installation
Fig. 3-1
PKA-RP60, 71, 100KAL
Fig. 3-2
A
K
J
I
100m
25
0
12.5
37.5
62.5
87.5
104.5
129.5
167
217
229.5
264
292
308.5
311
54
585
465.5
454
439
408.5
384.5
364
314
110
54
0
3
60
10
0
10
60
110
314
364
384
408.5
439
454
517.4
585
530.5
439
430.5
384
339
189
0
216.5
339
R37.5
349.2
384
439
449.2
15.5
0
25
50
75
100
117
125142
192
242
279.5
292
A
B
C
H
F
G
D
E
(mm)
PKA-RP60, 71, 100KAL
Fig. 3-3
A
C
D
E
B
A
Sleeve
B
Hole
C
(Indoors)
D
Wall
E
(Outdoors)
G
F
A
B
L
1170
365
H
E
J
*
M
I
D
C
295
K
(mm)
1
2
3
4
5
6
7
8
9
0
–