7
4
SPECIFICATION
1. Heat pump type Rating Conditions (ISO T1)
Service Ref. With Electric heater
PEHD-P1.6EAH
PEHD-P2EAH
Item
Without Electric heater
PEAD-P1.6EA
PEAD-P2EA
Function
Cooling
Heating
Cooling
Heating
Capacity
✻
1
Btu/h
15,300
16,700 (20,100)
18,900
21,000 (24,400)
W
4,500
4,900 (5,900)
5,550
6,150 (7,150)
Total input
✻
1
kW
1.75
1.80 (2.80)
2.44
2.22 (3.22)
Service Ref.
With Electric heater
PEHD-P1.6EAH
PEHD-P2EAH
Without Electric heater
PEAD-P1.6EA
PEAD-P2EA
Power supply
Single phase,50Hz,220-240V
Input
✻
2
kW
0.13
0.13 <1.13>
0.15
0.15 <1.15>
Running current
✻
2
A
0.55
0.55 <4.71>
0.63
0.63 <4.79>
Starting current
✻
2
A
–
–
–
–
External finish
Galvanized sheets
Heat exchanger
Plate fin coil
Fan
Fan (drive)
×
No.
Centrifugal (direct)
×
2
Fan motor output
kW
0.043 (at 70 Pa)
0.076 (at 70 Pa)
Airflow (Lo-Hi)
m
3
/min (CFM)
11-14 <388-494>
13.5-17 <477-600>
External static pressure
Pa (mmAq)
30/70
Booster heater
✻
2
kW
<1.0>
<1.0>
Operation control & Thermostat
Built in remote controller
Noise level (Lo-Hi)
dB
34-38
36-40
Unit drain pipe O.D
mm (in.)
32 (1-1/4)
Dimensions
W
mm (in.)
935 (36-13/16)
D
mm (in.)
700 (27-5/8)
H
mm (in.)
295 (11-5/8)
Weight
With Electric heater
kg (lbs)
35 (77)
35 (77)
Without Electric heater
kg (lbs)
33 (73)
33 (73)
Service Ref.
PUH-P1.6VGA/YGA
PUH-P2VGA/YGA
Power supply
Single phase,50Hz,220-240V / 3 phase,50Hz,380-415V (4 wires)
Input
kW
1.62
1.67
2.44
2.22
Running current
A
7.43/2.67
7.43/2.86
10.39/3.88
9.36/4.02
Starting current
A
36/20
74/30
External finish
Munsell 5Y 8/1
Refrigerant control
Linear Expansion Valve
Compressor
Hermetic
Model
RE277VHSM/RE277YFKM
NE38VMJM/NE38YEJM
Motor output
kW
1.3
1.7
Starter type
Line start
Protection devices
VGA…Inner thermostat, HP switch, Discharge thermo.
YGA…Thermal relay, Discharge thermo, HP switch, Anti-phase protector.
Crankcase heater
W
30
38
Heat exchanger
Plate fin coil
Fan
Fan (drive)
×
No.
Propeller (direct)
×
1
Propeller (direct)
×
1
Fan motor output
kW
0.070
0.070
Airflow
m
3
/min (CFM)
45 (1,590)
55 (1,940)
Defrost method
Reverse cycle
Noise level
Cooling
dB
46
48
Heating
dB
48
49
Dimensions
W
mm (in.)
900 (35-7/16)
D
mm (in.)
330+20 (13+3/4)
H
mm (in.)
650 (25-5/8)
855 (33-5/8)
Weight
kg (lbs)
55 (121)
71 (157)
Refrigerant
R407C
Charge
kg (lbs)
2.6 (5.7)
3.1 (6.8)
Oil (Model)
L
0.57 (Ester) MEL56
1.2 (Ester) MEL56
Pipe size O.D
Liquid
mm (in.)
9.52 (3/8)
Gas
mm (in.)
15.88 (5/8)
Connection method
Indoor side
Flared
Outdoor side
Flared
Between the indoor &
outdoor unit
Height difference
Max.40m
Piping length
Max.40m
Notes
1. Rating Conditions (ISO T1)
3. Above data based on indicated voltage
Indoor Unit: Single phase 240V 50Hz
Outdoor Unit: Single phase 240V 50Hz / 3 phase 415V 50Hz
2. Guaranteed operating range
✻
1 : ( ) Shows the total rating.
✻
2 : < > Shows only the booster heater r ating.
Indoor
Outdoor
Cooling
Upper limit
D.B.35
°
C, W.B.22.5
°
C
D.B.46
°
C
Lower limi
D.B.19
°
C, W.B.15
°
C
D.B.-5
°
C
Heating
Upper limit
D.B.28
°
C
D.B.24
°
C, W.B.18
°
C
Lower limi
D.B.17
°
C
D.B.-11
°
C, W.B.-12
°
C
OUTDOOR UNIT
REFRIGERANT PIPING
INDOOR UNIT
Cooling: Indoor:
D.B.27
°
C (80
°
F), W.B.19
°
C (66
°
F)
Outdoor: D.B.35
°
C (95
°
F), W.B.24
°
C (75
°
F)
Heating: Indoor:
D.B.20
°
C (68
°
F)
Outdoor: D.B.7
°
C (45
°
F), W.B.6
°
C (43
°
F)
Refrigerant piping length (one way): 5m (16ft)