31
Cooling only type
Rating Conditions (ISOT1)
Indoor ....... 220V 50Hz 1 phase Outdoor ........ 220V/380V 50Hz 1/3 phase
Indoor ....... 230V 50Hz 1 phase Outdoor ........ 230V/400V 50Hz 1/3 phase
Indoor ....... 240V 50Hz 1 phase Outdoor ........ 240V/415V 50Hz 1/3 phase
Service
Ref.
Indoor unit
PEAD-
P1.6EA
PEAD-P2EA
PEAD-
P2.5EA
PEAD-P3EA
PEAD-P4EA PEAD-P5EA PEAD-P6EA
Outdoor unit
PU-
P1.6VGA
PU-P2VGA
PU-
P2.5VGA1
PU-P3VGA
PU-P3YGA
PU-P4YGA
PU-P5YGA
PU-P6YGA
Mode
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Capacity (W)
4400
5450
6500
7500
7500
9500
12100
13900
Total input (kW)
1.66
2.34
2.61
3.29
3.29
3.76
4.81
5.72
Indoor
Input (kW)
0.12
0.13
0.15
0.30
0.30
0.52
0.54
0.56
Current (A)
0.55
0.60
0.69
1.39
1.39
2.41
2.50
2.59
Starting current (A)
–
–
–
–
–
–
–
–
Outdoor
Input (kW)
1.54
2.21
2.46
2.99
2.99
3.24
4.27
5.16
Current (A)
7.40
10.45
11.59
14.71
5.54
5.55
8.92
10.72
Starting current (A)
33
68
70
84
38
41
72
77
Service
Ref.
Indoor unit
PEAD-
P1.6EA
PEAD-P2EA
PEAD-
P2.5EA
PEAD-P3EA
PEAD-P4EA PEAD-P5EA PEAD-P6EA
Outdoor unit
PU-
P1.6VGA
PU-P2VGA
PU-
P2.5VGA1
PU-P3VGA
PU-P3YGA
PU-P4YGA
PU-P5YGA
PU-P6YGA
Mode
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Capacity (W)
4450
5500
6600
7600
7600
9600
12200
14000
Total input (kW)
1.71
2.39
2.65
3.35
3.35
3.83
4.87
5.81
Indoor
Input (kW)
0.13
0.14
0.16
0.35
0.35
0.57
0.59
0.61
Current (A)
0.55
0.61
0.70
1.55
1.55
2.53
2.62
2.69
Starting current (A)
–
–
-–
–
–
–
–
–
Outdoor
Input (kW)
1.58
2.25
2.49
3.00
3.00
3.26
4.28
5.20
Current (A)
7.42
10.38
11.32
14.09
5.46
5.48
8.59
10.36
Starting current (A)
35
71
74
89
40
43
76
81
Service
Ref.
Indoor unit
PEAD-
P1.6EA
PEAD-P2EA
PEAD-
P2.5EA
PEAD-P3EA
PEAD-P4EA PEAD-P5EA PEAD-P6EA
Outdoor unit
PU-
P1.6VGA
PU-P2VGA
PU-
P2.5VGA1
PU-P3VGA
PU-P3YGA
PU-P4YGA
PU-P5YGA
PU-P6YGA
Mode
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Cooling
Capacity (W)
4500
5550
6700
7700
7700
9700
12300
14100
Total input (kW)
1.75
2.44
2.68
3.41
3.41
3.90
4.93
5.90
Indoor
Input (kW)
0.13
0.15
0.17
0.40
0.40
0.62
0.64
0.66
Current (A)
0.55
0.63
0.72
1.70
1.70
2.64
2.72
2.79
Starting current (A)
–
–
–
–
–
–
–
–
Outdoor
Input (kW)
1.62
2.29
2.51
3.01
3.01
3.28
4.29
5.24
Current (A)
7.43
10.39
11.27
13.73
5.46
5.49
8.39
10.17
Starting current (A)
36
74
77
93
41
45
79
84