![Mitsubishi Electric NZ2GF-CCB User Manual Download Page 122](http://html.mh-extra.com/html/mitsubishi-electric/nz2gf-ccb/nz2gf-ccb_user-manual_1811813122.webp)
120
688
H
689
H
68A
H
68B
H
Blown fuse status
of another station
Whether a fuse blown error has occurred is stored.
0: Normal
1: Error
• The bits for the station number of the start station and the number of occupied stations are turned on.
• Reserved stations, station with the last station number, and stations later than that are excepted.
68C
H
68D
H
68E
H
68F
H
Other stations
switch change
status
Whether the setting of switches of other stations during data link has been changed is stored.
0: No change
1: Changed
• The bits for the station number of the start station and the number of occupied stations are turned on.
• Reserved stations, station with the last station number, and stations later than that are excepted.
690
H
Line status
Line status is stored.
0: Normal
1: Data link disabled (disconnected)
698
H
699
H
69A
H
69B
H
Station number in
use status
Whether station numbers are unique when the start station numbers of modules are different is stored.
0: Normal
1: Station number in use (start station number only)
• Reserved stations, station with the last station number, and stations later than that are excepted.
• Only the bit corresponding to the start station number turns on. This item is checked, and the result is
stored only upon data link start and the update of a parameter.
• For a CC-Link remote station with the transmission speed auto-tracking setting, whether the station
number is already used for other stations may not be detected.
Address
Name
Description
to
to
to
to
to
The numbers 1 to 64 in the table are station numbers.
b15
16
32
48
64
15
31
47
63
14
30
46
62
13
29
45
61
4
20
36
52
3
19
35
51
2
18
34
50
1
17
33
49
b14
b13
b12
b3
b2
b1
b0
688
H
689
H
68A
H
68B
H
to
to
to
to
to
The numbers 1 to 64 in the table are station numbers.
b15
16
32
48
64
15
31
47
63
14
30
46
62
13
29
45
61
4
20
36
52
3
19
35
51
2
18
34
50
1
17
33
49
b14
b13
b12
b3
b2
b1
b0
68C
H
68D
H
68E
H
68F
H
to
to
to
to
to
The numbers 1 to 64 in the table are station numbers.
b15
16
32
48
64
15
31
47
63
14
30
46
62
13
29
45
61
4
20
36
52
3
19
35
51
2
18
34
50
1
17
33
49
b14
b13
b12
b3
b2
b1
b0
698
H
699
H
69A
H
69B
H