En-1

n

  Do not install the unit by yourself (user).

  Incomplete installation could cause fire or electric shock, injury due to the unit 

falling, or leakage of water. Consult the dealer from whom you purchased the 

unit or a qualified installer.

n

  Perform the installation securely referring to the installation manual.

  Incomplete installation could cause fire or electric shock, injury due to the unit 

falling, or leakage of water. 

When installing the unit, use appropriate protective equipment and tools 

for safety.

  Failure to do so could cause injury.

n

  Install the unit securely in a place which can bear the weight of the unit.

  If the installation location cannot bear the weight of the unit, the unit could fall 

causing injury.

Perform electrical work according to the installation manual and be sure to 

use an exclusive circuit. Do not connect other electrical appliances to the 

circuit.

  If the capacity of the power circuit is insufficient or there is incomplete electrical 

work, it could result in a fire or an electric shock.

Do not damage the wires by applying excessive pressure with parts or 

screws.

  Damaged wires could cause fire.

Be sure to cut off the main power in case of setting up the indoor P.C. 

board or wiring works.

  Failure to do so could cause electric shock.

n

  Use the specified wires to connect the indoor and outdoor units securely 

and attach the wires firmly to the terminal block connecting sections so 

the stress of the wires is not applied to the sections.

  Incomplete connecting and securing could cause fire.

Do not install the unit in a place where inflammable gas may leak.

  If gas leaks and accumulates in the area around the unit, it could cause an 

explosion.

n

 Do not use intermediate connection of the power cord or the extension 

cord and do not connect many devices to one AC outlet.

  It could cause a fire or an electric shock due to defective contact, defective 

insulation, exceeding the permissible current, etc.

Be sure to use the parts provided or specified parts for the installation 

work.

  The use of defective parts could cause an injury or leakage of water due to a 

fire, an electric shock, the unit falling, etc.

When plugging the power supply plug into the outlet, make sure that there is 

no dust, clogging, or loose parts in both the outlet and the plug. Make sure 

that the power supply plug is pushed completely into the outlet. 

  If there is dust, clogging, or loose parts on the power supply plug or the outlet, it 

could cause electric shock or fire. If loose parts are found on the power supply 

plug, replace it.

Attach the electrical cover to the indoor unit and the service panel to the 

outdoor unit securely.

  If the electrical cover of the indoor unit and/or the service panel of the outdoor 

unit are not attached securely, it could result in a fire or an electric shock due 

to dust, water, etc.

When installing, relocating, or servicing the unit, make sure that no sub-

stance other than the specified refrigerant (R410A) enters the refrigerant 

circuit.

  Any presence of foreign substance such as air can cause abnormal pressure 

rise and may result in explosion or injury. The use of any refrigerant other than 

that specified for the system will cause mechanical failure, system malfunction, 

or unit breakdown. In the worst case, this could lead to a serious impediment 

to securing product safety.

Do not discharge the refrigerant into the atmosphere. If refrigerant leaks 

during installation, ventilate the room.

  If refrigerant comes in contact with a fire, harmful gas could be generated. Refriger

-

ant leakage may cause suffocation. Ventilate the room.

Check that the refrigerant gas does not leak after installation has been 

completed.

  If refrigerant gas leaks indoors, and comes into contact with the flame of a fan 

heater, space heater, stove, etc., harmful substances will be generated.

Use appropriate tools and piping materials for installation. 

  The pressure of R410A is 1.6 times more than R22. Not using appropriate 

tools or materials and incomplete installation could cause the pipes to burst 

or injury. 

When pumping down the refrigerant, stop the compressor before discon-

necting the refrigerant pipes.

  If the refrigerant pipes are disconnected while the compressor is running and 

the stop valve is open, air could be drawn in and the pressure in the refrigera

-

tion cycle could become abnormally high. This could cause the pipes to burst 

or injury. 

When installing the unit, securely connect the refrigerant pipes before 

starting the compressor.

  If the compressor is started before the refrigerant pipes are connected and 

when the stop valve is open, air could be drawn in and the pressure in the 

refrigeration cycle could become abnormally high. This could cause the pipes 

to burst or injury.

Fasten a flare nut with a torque wrench as specified in this manual.

  If  fastened  too  tight,  a  flare  nut  may  break  after  a  long  period  and  cause 

refrigerant leakage.

The unit shall be installed in accordance with national wiring regulations. 

n

  Ground the unit correctly.

  Do not connect the ground to a gas pipe, water pipe, lightning rod or telephone 

ground. Defective grounding could cause electric shock.

n

  Be sure to install a Ground Fault Interrupt (GFI) circuit breaker.

  Failure to install a Ground Fault Interrupt (GFI) circuit breaker may result in 

electric shock or fire.

1-2. SPECIFICATIONS

1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

•  Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.

•  Be sure to observe the warnings and cautions specified here as they include important items related to safety.

•  After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.

 

CAUTION

(Could lead to serious injury in particular environments when operated incorrectly.)

n

 Perform the drainage/piping work securely according to the installation 

manual.

  If there is defect in the drainage/piping work, water could drop from the unit, 

soaking and damaging household goods.

n

  Do not touch the air inlet or the aluminum fins of the outdoor unit.

  This could cause injury. 

n

  Do not install the outdoor unit where small animals may live.

  If small animals enter and touch the electric parts inside the unit, it could 

cause a malfunction, smoke emission, or fire. Also, advise user to keep the 

area around the unit clean. 

 

WARNING

(Could lead to death, serious injury, etc.)

Required Tools for Installation

Phillips screwdriver

Level

Scale

Utility knife or scissors

Torque wrench

Wrench (or spanner)

5/32 in. (4 mm) hexagonal 

wrench

Flare tool for R410A

Gauge manifold for R410A

Vacuum pump for R410A

Charge hose for R410A

Pipe cutter with reamer

 ENGLISH

CONTENTS

1. BEFORE INSTALLATION

 ............................................................1

2. OUTDOOR UNIT INSTALLATION ...............................................4

3. FLARING WORK AND PIPE CONNECTION

 ...............................5

4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN

 ......... 5

5. PUMPING DOWN ........................................................................7

Model

Power supply

Pipe length and height difference 

*1, *2, *3, *4, *5, *6

Rated Voltage

Frequency Max. pipe length per indoor 

unit / for multi-system

Max. height difference

Max. no. of bends per in-

door unit / for multi system Refrigerant adjustment A *7

MXZ-3C24NA2

MXZ-3C30NA2

MXZ-4C36NA2

208 / 230 V

60 Hz

82 ft. (25 m) / 230 ft. (70 m)

49 ft. (15 m)

25 / 70

1.08 oz each 5 ft. (20 g/m)

*1 Never use pipes with thickness less than specified. The pressure resistance 

will be insufficient.

*2 Use a copper pipe or a copper-alloy seamless pipe.

*3 Be careful not to crush or bend the pipe during pipe bending.

*4 Refrigerant pipe bending radius must be 4 in. (100 mm) or more.

*5 Insulation material : Heat resisting foam plastic 0.045 specific gravity

*6 Be sure to use the insulation of specified thickness. Excessive thickness may 

cause incorrect installation of the indoor unit and insufficient thickness may 

cause dew drippage.

*7 If pipe length exceeds 98 ft. (30 m), additional refrigerant (R410A) charge 

is required. (No additional charge is required for pipe length less than 98 ft. 

(30 m).)

  Additional refrigerant (ft.) = A × 

(pipe length (ft.) – 98)

5

  Additional refrigerant (m) = A × (pipe length (m) – 30)

1.  BEFORE INSTALLATION

WG79A686H01_en.indd   1

11/24/2015   9:04:54 AM

Summary of Contents for MXZ-3C30NA2

Page 1: ...ATEUR Cette notice ne décrit que l installation de l appareil extérieur Lors de l installation de l appareil intérieur consultez la notice d installation de cet appareil Toute altération structurelle requise pour l installation doit être conforme aux exi gences du code du bâtiment local Manual de instalación Para el INSTALADOR En este manual sólo se describe la instalación de la unidad exterior Pa...

Page 2: ...ssure of R410A is 1 6 times more than R22 Not using appropriate tools or materials and incomplete installation could cause the pipes to burst or injury n When pumping down the refrigerant stop the compressor before discon necting the refrigerant pipes If the refrigerant pipes are disconnected while the compressor is running and the stop valve is open air could be drawn in and the pressure in the r...

Page 3: ...the sides of the unit is required 2 Front blowing side open As long as space indicated in the figure is provided it is allowed to install the unit where obstacles are behind and on the sides of the unit No obstacle above the unit FREE SPACE REQUIRED AROUND OUTDOOR UNIT Service space When installing the unit in an area that is enclosed with walls such as a verandah be sure to have enough space as s...

Page 4: ...w for I 2 to 7 K Wall hole sleeve 1 L Soft PVC hose 19 32 in 15 mm inner diameter or hard PVC pipe VP16 for drain socket 1 1 Note Place indoor outdoor unit connecting wire B and power supply cord A at least 3 ft 1 m away from the TV antenna wire The Q ty for B to K in the above table is quantity to be used per indoor unit More than 3 15 16 in 100 mm Open as a rule More than 19 11 16 in 500 mm if t...

Page 5: ...8 Connect power supply cord A 9 Close the service panel securely Make sure that 3 2 PIPE CONNEC TION is completed Connecting order Connect the terminal block in following order A B C D P CONNECTING WIRES AND CONNECTING GROUND WIRE Use solid conductor Min AWG14 or stranded conductor Min AWG14 Use double insulated copper wire with 600 V insulation Use copper conductors only Follow local electrical c...

Page 6: ...gas pipe The stop valves are fully closed and covered in caps in their initial state 2 Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe side of the outdoor unit 3 Run the vacuum pump Vacuumize for more than 15 minutes 4 Check the vacuum with gauge manifold valve then close gauge manifold valve and stop the vacuum pump 5 Leave as it is for one or two minute...

Page 7: ...NIT COOL DRY HEAT Description of the function With this function once the operation mode is locked to either COOL DRY mode or HEAT mode the air conditioner operates in that mode only Changing the setting is required to activate this function Please explain about this function to your customers and ask them whether they want to use it How to lock the operation mode 1 Be sure to turn off the main po...

Page 8: ...hen the correction completed without error do not press the piping wiring correction switch SW871 again When the result is Not completed press the piping wiring correction switch SW871 again to cancel this function Then confirm the wiring and piping combination in a conventional manner by operating the indoor units one by one The operation is done while the power is supplied Make sure not to conta...

Page 9: ...z pas le réfrigérant dans l atmosphère En cas de fuite de réfrigérant pendant l installation aérez la pièce Tout contact entre le réfrigérant et une flamme pourrait provoquer l émission de gaz toxiques Des fuites de réfrigérant peuvent provoquer une asphyxie Aérez la pièce n A la fin de l installation aucune fuite de réfrigérant ne doit être présente sur le circuit En cas de fuite de réfrigérant d...

Page 10: ...e est basse veillez à observer les instructions ci dessous N installez jamais l unité externe dans un endroit où le côté présentant l entrée la sortie d air risque d être directement exposé au vent Pour protéger l unité externe du vent installez la de façon à ce que l entrée d air soit face au mur Pour éviter toute exposition au vent il est recommandé d installer un écran de protection du côté de ...

Page 11: ...ie doit être fixée sur un mur contenant des métaux de l étain p ex ou un treillis métallique utiliser un morceau de bois traité d une épais seur de 25 32 po 20 mm minimum entre le mur et la tuyauterie ou isoler la tuyauterie en lui appliquant 7 à 8 couches de ruban isolant en vinyle Pour utiliser la tuyauterie existante effectuer un cycle COOL REFROI DISSEMENT de 30 minutes et lancer l aspiration ...

Page 12: ...électrique local CÂBLE D ALIMENTATION ÉLECTRIQUE ET CÂBLE DE MISE À LA TERRE Utiliser un conducteur massif ou toronné min AWG12 Utiliser des conducteurs en cuivre uniquement Respecter le code électrique local AVERTISSEMENT Utiliser le câble de connexion conforme aux normes techniques pour raccorder les unités interne et externe et fixer le câble fermement sur la bloc de sortie de façon que le côté...

Page 13: ...Serrez le bouchon de l ouverture de service pour recréer les conditions d origine 10 Test de contrôle des fuites 3 2 RACCORDEMENT DES TUYAUX 1 Appliquez une fine couche d huile réfrigérante G sur les embouts évasés des tuyaux ainsi que sur les raccords de tuyau de l appareil extérieur 2 Alignez la partie médiane du tuyau sur les raccords de tuyau de l appareil extérieur et serrez les écrous évasés...

Page 14: ... DE FONCTIONNEMENT DE L APPAREIL EXTÉRIEUR REFROIDISSEMENT DÉSHUMIDIFICATION CHAUFFAGE Description de la fonction Lorsque cette fonction est sélectionnée si le mode de fonctionnement est blo qué sur COOL DRY REFROIDISSEMENT DÉSHUMIDIFICATION ou HEAT CHAUFFAGE le climatiseur fonctionne uniquement dans ce mode Il est nécessaire de modifie la configration pour pouvoir sélectionner cette fonction Prés...

Page 15: ...en marche trop rapide Lorsque le compresseur s arrête le dispositif de protection contre la remise en marche à trop brève échéance s enclenche Le compresseur restera arrêté trois minutes avant de se remettre en marche afin de protéger le climatiseur Fonction de correction de câblage tuyauterie L appareil est équipé d une fonction qui permet de corriger les branchements de câblage et de tuyauterie ...

Page 16: ... sistema ocasionará fallos mecánicos malfuncionamiento del sistema o averías en la unidad En el peor de los casos esto podría llegar a ser un serio impedimento para garantizar el uso seguro del producto n No descargue el refrigerante en el ambiente Si se producen fugas de refrige rante durante la instalación ventile la habitación Si el refrigerante entra en contacto con una llama podría generarse ...

Page 17: ...xterior sea baja observe las instrucciones siguientes No instale nunca la unidad exterior en un lugar en el que el lado de entra da salida de aire quede expuesto directamente al viento Para evitar la exposición al viento instale la unidad exterior con el lado de entrada de aire hacia la pared Para evitar la exposición al viento se recomienda instalar una placa de flectora en el lado de salida de a...

Page 18: ... si la parte delantera y ambos lados están abiertos Después de la prueba de fugas aplique material aislante de modo que no queden huecos Cuando los tubos deban instalarse en una pared con contenido metálico placas de latón o rejillas metálicas ponga un trozo de madera tratada químicamente de 25 32 pulg 20 mm o más de grosor entre la pared y los tubos o envuelva los tubos con 7 u 8 vueltas de cinta...

Page 19: ... de 600 V Use únicamente conductores de cobre Siga la normativa eléctrica local CABLE DE ALIMENTACIÓN Y CABLE DE TIERRA Utilice un conductor sólido o trenzado con un calibre mín AWG12 Use únicamente conductores de cobre Siga la normativa eléctrica local ATENCIÓN Conecte las unidades interior y exterior con el cable de conexión normalizado destinado a este fin y sujete bien el cable al panel de ter...

Page 20: ... la tapa de la abertura de servicio de la válvula de retención situada en el lado de la tubería de gas de la unidad exterior Inicialmente las válvulas de retención están completamente cerradas y cubiertas con sus tapas 2 Conecte la válvula colectora de manómetro y la bomba de vacío al puerto de servicio de la válvula de retención en el lado de la tubería del gas de la unidad exterior 3 Ponga en fu...

Page 21: ...IÓN 4 4 REDUCIR EL RUIDO DE FUNCIONAMIENTO DE LA UNIDAD EXTERIOR Descripción de la función Con esta función una vez que el modo de funcionamiento se ha bloqueado en COOL DRY REFRIGERACIÓN DESHUMIDIFICACIÓN o HEAT CALEFAC CIÓN el acondicionador de aire funciona únicamente en ese modo Es necesario cambiar el ajuste para activar esta función Explique esta function a sus clientes y pregúnteles si dese...

Page 22: ...ba de funcionamiento de las unidades una a una Acerca del mecanismo de protección de la reanudación Una vez se haya detenido el compresor el dispositivo de prevención de la reanudación se activa de forma que el compresor no vuelve a ponerse en funcionamiento durante 3 minutos para proteger el acondicionador de aire Función de corrección de conexiones tuberías Esta unidad tiene una función de corre...

Page 23: ......

Page 24: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WG79A686H01 ...

Reviews: