84
Check of outdoor fan motor
• Fan motor does not operate or stops operating shortly after starting the operation.
Disconnect CN932 and measure the
resistance of the outdoor fan motor.
Turn ON the breaker.
Rotate the outdoor fan motor manually and
measure the voltage of CN931.
Between (+) and (-)
Between (+) and (-)
Between (+) and (-)
Is the resistance of outdoor fan motor
normal? (Refer to 11-5.)
Does the outdoor fan motor rotate smoothly?
Does the voltage between each terminal
become 5V DC and 0V DC repeatedly?
Replace the outdoor fan motor.
Replace the inverter P.C. board or the outdoor
control P.C. board.
No
Yes
Yes
No
Yes
No
CN931
CN932
Outdoor control P.C. board
MXZ-2D
MXZ-4D83VA/5D102VA
Inverter P.C. board
MXZ-2D33VA/2D40VA/2D53VA/2D53VAH
MXZ-4D83VA/5D102VA
OBH626B