14
OPERATING PROCEDURE
PHOTOS
4. Removing the compressor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the soundproof felt.
(3) Remove the screws fixing the relay panel.
(4) Remove the terminal cover.
(5) Pull out the lead wires from the glass terminal of the com-
pressor.
(6) Recover gas from the refrigerant circuit.
NOTE :
Recover gas from the pipes until the pressure gauge
shows 0 kg/cm
2
(0MPa).
(7) Disconnect the welded part of the suction pipe and
discharge pipe.
(8) Remove the nuts fixing the compressor.
(9) Remove the compressor.
Photo 5
Compressor
Discharge
pipe
Compressor set nuts
(3 places)
Terminal
cover
Suction
pipe
MU-C08/10VC
Photo 6
Compressor
Discharge
pipe
Compressor set nuts
(3 places)
Terminal
cover
Suction
pipe
MU-C13VC
Summary of Contents for MU-GD08ND
Page 6: ...6 WIRING DIAGRAM 5 MU C08VC MU C10VC MU C13VC MU GD08ND MU GD10ND ...
Page 18: ......
Page 19: ......