4
SPECIFICATION
3
Outdoor model
MU-GD08ND -
C1
MU-GD10ND -
C1
MU-GD12ND -
C1
Function
Cooling
Power supply
Single phase
220-230V, 60Hz
Capacity
Capacity
kW
2.2-2.2
2.9-2.9
3.6-3.6
Dehumidi
fi
cation
R
/h
0.1
0.45
1.1
Air
fl
ow
K
/h
1896-1962
1452-1524
2106-2124
Electrical data
Power outlet
A
10
10
10
Running current (Total)
A
3.19-3.24
4.31-4.31
5.7-5.7
Power input (Total)
W
680-685
930-930
1210-1210
Power factor (Total)
%
97-92
98-94
96-92
Starting current
A
19
26
40
Compressor motor current
A
2.67-2.71
3.86-3.85
5.14-5.13
Fan motor current
A
0.330-0.340
0.260-0.270
0.370-0.380
Coef
fi
cient of performance (C.O.P)
3.24-3.21
3.12-3.12
2.98-2.98
Compressor
Model
KS098NARC
RH145NHNT
RH189NRAT
Output
W
500
700
900
Winding
resistance (at 20
:
)
Ω
C-R 3.54
C-S 4.90
C-R 2.74
C-S 3.78
C-R 1.50
C-S 2.33
Fan
motor
Model
RA6V21-BE
RA6N21-AB
RA6V33-MC
Winding
resistance (at 20
:
)
Ω
WHT-BLK 252
BLK-RED 278
WHT-BLK 384
BLK-RED 259
WHT-BLK 141
BLK-RED 175
Dimensions WxHxD
mm
684x540x255
800x550x285
Weight
kg
22
34
35
Special
remarks
Sound level
dB
46-47
46-46
50-51
Fan speed
rpm
820-830
690-720
980-990
Fan speed regulator
1
Refrigerant
fi
lling capacity (R22)
kg
0.55
1.10
Refrigeration oil (Model)
cc
300(NM56)
520(NM56)
NOTE: Test conditions are based on CNS 14464
Cooling : Indoor
Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor
Dry-bulb temperature 35°C Wet-bulb temperature 24°C
Refrigerant piping length (one way) 7.5 m