4. Removing the compressor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the relay panel.
(3) Remove the soundproof felt.
(4) Remove the terminal cover.
(5) Pull out the lead wires from the glass terminal of the com-
pressor.
(6) Recover gas from the refrigerant circuit.
NOTE :
Recover gas from the pipes until the pressure gauge
shows 0 kg/cm
2
(0MPa).
(7) Disconnect the welded part of the suction pipe and dis-
charge pipe.
(8) Remove the nuts fixing the compressor and the compres-
sor.
Glass
terminal
Compressor
Suction pipe
Discharge pipe
Compressor
nuts
Photo 6
MU-GD10ND
Glass
terminal
Discharge
pipe
Suction
pipe
Compressor nuts
(3 places)
Compressor
MU-GD12ND