OPERATING PROCEDURE
PHOTOS/FIGURES
2. Removing the indoor electrical box
(Photos 5, 6, 7, 8)
(1) Remove the front panel, the horizontal vanes (uppler R/
L), (lower R/L), the corner boxes (R) (L), and the panels
(U) (R) (L) (refer to section 1).
(2) Remove the erath wire.
(3) Remove the screw of the V.A. clamp, and remove the
V.A. clamp (Photo 5).
(4) Remove the screw of the electrical cover, and remove
the electrical cover (Photo 6).
(5) Disconnect the following connectors (Photo 8):
<Indoor electronic control P.C. board>
CN1J1 (DISPLAY AND i-see SENSOR ASSEMBLY)
(6) Remove the DISPLAY AND i-see SENSOR
ASSEMBLY (Photo 7).
(7) Disconnect the following connector (Photo 8):
<Indoor electronic control P.C. board>
CN110 (Wi-Fi assembly)
CN2T1 [Interlock switch (Air purifying device)]
CN161 (Switch buzzer P.C. board)
CN211 (Indoor fan motor)
CN151 (Vane motors)
CN112 (Indoor coil thermistor)
CN1T1 (Air purifying device)
(8) Remove the electrical box.
48
Photo 5
Photo 7
Remove the DISPLAY AND
i-see Sensor ASSEMBLY to
the direction of .
DISPLAY AND i-see
SENSOR ASSEMBLY
(Refer to Photo 11)
Photo 6
Electrical cover
Screw of the
terminal block
Tab of the earth wire
Screw of the
electrical cover
Screw of the
V.A. clamp
OBH902A