4
SPECIFICATION
3
Indoor model
MSZ-HR25VF
MSZ-HR35VF
MSZ-HR42VF
MSZ-HR50VF
Power supply
Single phase 230 V, 50 Hz
Electrical data
Power input
*1
Cooling
W
20
28
32
39
Heating
20
28
32
39
Running
current *1
Cooling
A
0.20
0.27
0.30
0.36
Heating
0.20
0.27
0.30
0.36
Fan motor
Model
RC0J30-CV
RC0J30-CV
RC0J30-CV
RC0J30-CV
Current *1
Cooling
A
0.20
0.27
0.30
0.36
Heating
0.20
0.27
0.30
0.36
Dimensions W × H × D
mm
838 × 280 × 228
838 × 280 × 228
838 × 280 × 228
838 × 280 × 228
Weight
kg
8.5
8.5
9.0
9.0
Special remarks
Air direction
5
5
5
5
Airflow
Cooling
Super High
m
3
/h
582
702
786
786
High
432
468
648
672
Med.
324
336
522
522
Low
216
216
360
384
Heating
Super High
606
630
804
870
High
444
444
648
672
Med.
324
324
474
498
Low
198
198
336
366
Sound level
Cooling
Super High
dB(A)
43
46
45
45
High
37
38
39
40
Med.
30
31
34
36
Low
21
22
24
28
Heating
Super High
43
44
46
47
High
37
37
40
41
Med.
30
30
32
34
Low
21
21
24
27
Fan speed
Cooling
Super High
rpm
1,120
1,280
1,130
1,130
High
900
950
970
1,000
Med.
730
750
830
860
Low
550
550
630
660
Heating
Super High
1,150
1,180
1,150
1,220
High
920
920
970
1,000
Med.
730
730
770
800
Low
520
520
600
640
Fan speed regulator
4
4
4
4
Remote controller model
RH18A
RH18A
RH18A
RH18A
NOTE
: Test conditions are based on ISO 5151.
Cooling: Indoor Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C Wet-bulb temperature 24°C
Heating: Indoor Dry-bulb temperature 20°C Wet-bulb temperature -
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
*1 Measured under rated operating frequency.
Specifications and rated conditions of main electric parts
Fuse
(F11)
T3.15AL250V
Horizontal vane motor
(MV)
12 V DC
Varistor
(NR11)
470 V
Terminal block
(TB)
3P
OBH822B