2
TECHNICAL CHANGES
1
MSH-C18SV -
➔
MSH-C18TV -
1. Rated voltage has changed to 230V.
2. Remote controller has changed.
• SLEEP MODE function has been removed.
• ECONO COOL operation has added.
• SWING button has been removed, but SWING MODE function has available by VANE CONTROL button.
3. Indoor electronic control P.C. board has changed.
MSH-C24TV -
New model
MUH-C18SV -
➔
MUH-C18TV -
1. Path of heat exchanger has changed.
2. Temperature of defrosting control has changed. (-3
:
➜
-2.7
:
)
3. Capillary tube has changed.
[
{
3.0
o
{
1.6
o
750 (2pcs)
➜
{
3.0
o
{
1.4
o
600 (2pcs),
{
3.0
o
{
2.0
o
500
➜
{
3.0
o
{
2.0
o
850,
{
3.0
o
{
2.0
o
350 has
removed.]
4. Refrigerant filling capacity has changed. (1.70kg
➜
1.60kg)
MUH-C24TV -
New model
E1
E1
E1
E1
E1
E1
OB279-1.qxp 2/15/01 10:44 AM Page 2