23
MICROPROCESSOR CONTROL
9
Once the operation mode are set, the same operation mode
can be repeated by simply turning the OPERATE/STOP
(ON/OFF) button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to
protect system from overload and compressor will not restart
for 3 minutes.
9-1. “I FEEL CONTROL” (
) OPERATION
(1) Press OPERATE/STOP (ON/OFF) button on the remote
controller. OPERATION INDICATOR lamp of the indoor
unit turns on with a beep tone.
(2) Select mode with the OPERATION SELECT button “I
FEEL CONTROL”.
(3) The operation mode is determined by the room tempera-
ture at start-up of the operation.
lighted
not lighted
Approx. 2
:
or more
Difference
between target
temperature
and room
temperature
Approx. 2
:
or less
This shows that the
air conditioner is
operating to reach
the target temperature.
Please wait until the
target temperature is
obtained.
This shows that the
room temperature is
approaching the
target temperature.
Operation state
Indication
Operation Indicator
Operation Indicator lamp
The operation indicator at the right side of the indoor
unit indicates the operation state.
• The following indication does not depend on the shape
of lamp.
INDOOR UNIT DISPLAY SECTION
WIRELESS REMOTE CONTROLLER
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
• Once the mode is fixed, the mode does not change by
room temperature afterwards.
• Under the ON-TIMER (
) operation, mode is deter-
mined according to the room temperature at the set time
the operation starts.
• When the system is stopped on the remote controller,
and restarted within 2 hours in “I FEEL CONTROL” (
)
mode, the system operates in previous mode automati-
cally regardless of the room temperature.
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
HEAT mode of
"I FEEL CONTROL"
Initial room temperature
25
:
or more
23
:
to 25
:
less than 23
:
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
When the system is restarted after 2 hours and more, the
operation mode is determined by the room temperature
at start-up of the operation.
Restart
COOL mode of
“I FEEL CONTROL”
Restart
COOL or DRY or
HEAT mode of “I FEEL
CONTROL” that deter-
mined by room tem-
perature at start-up of
the operation.
MSH-C18TV -
MSH-C24TV -
E1
E1
ON/OFF
FAN
TOO
WARM
TOO
COOL
VANE
MODE
ECONO COOL
STOP
START
HR.
MIN.
I FEEL COOL
HEAT DRY
RESET CLOCK
OPERATION SELECT button
FAN SPEED CONTROL button
OFF-TIMER button
HR. button
MIN. button
(TIME SET button)
ON-TIMER button
RESET button
ECONO COOL button
VANE CONTROL button
CLOCK SET button
ON/OFF
TOO
COOL
PM
AM
TOO
WARM
Signal transmitting section
Operation display section
OPERATE /STOP
(ON /OFF)button
TEMPERATURE buttons
MUH-C18TV -
MUH-C24TV -
E1
E1
OB279-1.qxp 2/15/01 10:44 AM Page 23