Job Name:
Location:
Date:
Purchaser:
Engineer:
Submitted to:
For Reference Approval Construction
System Designation:
Schedule No.:
© 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC.
3400 Lawrenceville Suwanee Rd
Suwanee, GA 30024
Tele: 678-376-2900 • Fax: 800-889-9904
Toll Free: 800-433-4822 (#3)
www.mehvac.com
Specifications are subject to change without notice.
MRC1 CABLE
• Connects MIFH1 Wireless Receiver to five-
pin CN105 on indoor unit control board
• Five-conductor wire with preterminated ends
• Length: 6-1/2' (2 m)
SUBMITTAL DATA: MHK1 REMOTE CONTROLLER KIT FOR M-SERIES AND P-SERIES
FORM# MHK1 - 201108
RedLINK is a trademark of Honeywell, Inc.
MRCH1 REMOTE CONTROLLER
• For use with P-Series NHA4
systems, SEZ-4/SUZ one-to-
one systems, SLZ/SUZ
one-to-one systems, MXZ-B
multi-zone systems, MSY/MSZ,
and MFZ indoor units
• Backlit, easy-to-read display
• Supports both Fahrenheit and
Celsius
• User functions allow user to set:
- On/Off
- Operation modes cool,heat, drying, fan
- Set temperature (separate dual set points for heat and cool)
- Fan speed setting
- Airflow direction
• Day/Time display with a 12-hour clock
• Filter sign display
• Optimal start
• Adjustable auto deadband
• Space temperature offset adjustment
• Display outside temperature and humidity (requires optional
MOS1, sold separately)
• Hold function
• Temporary schedule override
• Reset to factory default
• Auto lock display
• Timer Operation:
- Daily Timer: On/Off times can be set up to 4 times per day in
15-minute increments.
- Weekly Timer: On/Off times can be set up to 4 times per day of
the week in 15-minute increments. Choice of 5-2 and 5-1-1
weekly schedules for heat, cool, auto (separate for each mode)
- Auto-off Timer: Turns indoor unit Off at scheduled time up to
24 hours in advance
• Room Temperature: Displays room temperature sensed either at
the indoor unit or at the remote controller (default)
• Set temperature range limits (dependent on the system connected):
Cooling from 50° to 99°F
Heating from 40° to 90°F
Auto from 50° to 90°F with dual temperature setting
MHK1 REMOTE CONTROLLER KIT INCLUDES:
MIFH1 Wireless receiver
MOS1
Outside
Air Sensor
(Optional)
MCCH1
Portable
central
controller
Mr.Slim Outdoor Unit
MRCH1
Remote controller
r
• Diagnostics: Displays and records error codes
• No addressing required
• Can be integrated with other RedLINK™ devices
• Wiring: Connects using five-conductor cable from MIFH1
Wireless Receiver (cable included) to indoor unit; wireless RF
from the MIFH1 Wireless Receiver to the MRCH1 Remote
Controller
• Dimensions: 3-9/16" H x 5-13/16" W x 1-1/2" D (147 x 38 x
91mm)
• Uses two “AA” alkaline batteries (included)
MIFH1 WIRELESS RECEIVER
• Mounts next to or near indoor units
to allow MRCH1 Remote
Controller operation of P-Series
NHA4 systems, SEZ-4/SUZ one-
to-one systems, SLZ/SUZ one-to-
one systems , MXZ-B multi-zone
systems, MSY/MSZ, and MFZ indoor
units
• Dimensions: 6-7/16” H x 3-1/4” W x 1-5/16”
D (164 x 82.5 x 34 mm)
OPTIONAL ACCESSORIES
□ Portable Central Controller (MCCH1; for use with Wireless Remote
Controller Kit MHK1)*
□ Outdoor Air Sensor (MOS1; for use with Wireless Remote
Controller Kit MHK1)*
*See Submittal for information on each option.
KWHS
■
Summary of Contents for Mr.Slim MSY-D30NA
Page 41: ...7 MUZ D30NA MUZ D30NA U1 MUZ D36NA MUZ D36NA U1 5 WIRING DIAGRAM ...
Page 42: ...8 MUZ D30NA 1 MUZ D30NA U2 MUZ D36NA 1 MUZ D36NA U2 ...
Page 43: ...9 MUY D30NA MUY D36NA ...
Page 44: ...10 MUY D30NA 1 MUY D36NA 1 ...
Page 139: ...13 MUZ GE09NA MUZ GE12NA 5 WIRING DIAGRAM MUZ GE09NA2 MUZ GE12NA2 OBH549G ...
Page 140: ...14 MUZ GE09NAH MUZ GE12NAH MUZ GE09NAH2 MUZ GE12NAH2 OBH549G ...
Page 141: ...15 MUY GE09NA MUY GE12NA MUY GE09NA2 MUY GE12NA2 OBH549G ...
Page 142: ...16 MUZ GE15NA 1 MUZ GE15NA OBH549G ...
Page 143: ...17 MUZ GE15NAH MUZ GE15NA2 OBH549G ...
Page 144: ...18 MUY GE15NA MUZ GE15NAH2 OBH549G ...
Page 145: ...19 MUY GE15NA 1 MUY GE15NA2 OBH549G ...
Page 146: ...20 MUZ GE18NA MUZ GE18NA 1 OBH549G ...
Page 147: ...21 MUZ GE18NAH MUY GE18NA OBH549G ...
Page 148: ...22 MUY GE18NA 1 OBH549G ...
Page 149: ...23 MUZ GE24NA OBH549G ...
Page 150: ...24 MUY GE24NA OBH549G ...
Page 199: ...73 OBH549G ...