![Mitsubishi Electric MR-JET User Manual Download Page 107](http://html.mh-extra.com/html/mitsubishi-electric/mr-jet/mr-jet_user-manual_1811808107.webp)
4 APPLICABLE FUNCTIONS
4.6 Torque limit
105
4
4.6
Torque limit
The torque limit function limits the torque generated by the servo motor.
The following torque limit can be set.
• When setting the torque above the maximum torque of the servo motor, the torque is limited by the
maximum torque of the servo motor.
• Servo parameters that are mapped to an object from the controller will overwrite those written from the
engineering tool.
Precautions
• If the torque limit is canceled during servo-lock, the servo motor may suddenly rotate, depending on the amount of the
position deviation from the command position.
• When using the torque limit, check that [Pr. PB06 Load to motor inertia ratio/load to motor mass ratio] is set properly.
Improper settings may cause an unexpected operation such as an overshoot.
• When "0.0" is set, no torque is generated.
Setting method
Servo parameter setting
The maximum torque is always limited by the value of [Pr. PA11 Forward rotation torque limit] and [Pr. PA12 Reverse rotation
torque limit] during operation.
Set the rated torque at 100.0 [%].
Relation between servo parameters and objects
[Pr. PA11] and [Pr. PA12] is used for [Positive torque limit value (Obj. 60E0h)] or [Negative torque limit value (Obj. 60E1h)].
For [Pr. PA14 Travel direction selection] and [Pr. PC29 POL reflection selection at torque mode ], the relationship between
objects and servo parameters that limit the torque changes as follows.
Item
Outline
Internal torque limit
The maximum torque is limited by the value of [Pr. PA11 Forward rotation torque limit] and [Pr.
PA12 Reverse rotation torque limit].
Servo parameter
Symbol
Name
Outline
PA11
TLP
Forward rotation torque limit
Set the servo parameter when limiting the torque of the servo motor for
CCW power running or CW regeneration.
PA12
TLN
Reverse rotation torque limit
Set the servo parameter when limiting the torque of the servo motor for
CW power running or CCW regeneration.
PE53
TLMX1
Maximum torque limit 1
When [Pr. PC78.1 Maximum torque limit 1 selection] is set to "1"
(enabled), the torque generated by the servo motor can be limited with
this parameter.
Setting value
[Pr. PA11 Forward rotation torque
limit]
[Pr. PA12 Reverse rotation torque
limit]
[Pr. PC29.3]
[Pr. PA14]
0: Enabled
0
[Positive torque limit value (Obj. 60E0h)]
[Negative torque limit value (Obj. 60E1h)]
1
[Negative torque limit value (Obj. 60E1h)]
[Positive torque limit value (Obj. 60E0h)]
1: Disabled
0
[Positive torque limit value (Obj. 60E0h)]
[Negative torque limit value (Obj. 60E1h)]
1
[Positive torque limit value (Obj. 60E0h)]
[Negative torque limit value (Obj. 60E1h)]
[Pr. PC78.1] setting value
Torque limit set by [Max torque (Obj. 6072h)]
0: [Pr. PE53] Disabled
Disabled
([Max torque (Obj. 6072h)] returns the maximum torque of the servo motor.)
1: [Pr. PE53] Enabled
Enabled
(The torque limit function set by [Pr. PE53] and [Max torque (Obj. 6072h)] is enabled.)