![Mitsubishi Electric MR-JET User Manual Download Page 100](http://html.mh-extra.com/html/mitsubishi-electric/mr-jet/mr-jet_user-manual_1811808100.webp)
98
4 APPLICABLE FUNCTIONS
4.3 Drive recorder
■
Digital channel
*1 This signal cannot be used.
Setting value
Symbol
Name
Classification
0000
CSON
Servo ON command
DI
0001
LSP
Forward rotation stroke end
0002
LSN
Reverse rotation stroke end
0005
PC
Proportional control
0006
RES
Reset
0012
EM2/1
Forced stop
0013
CRDY
Ready-on command
0016
STO1
STO1
0017
STO2
STO2
001A
CDP2
Gain switching selection 2
001B
CDP
Gain switching selection
0049
CFLS
Controller upper stroke limit signal being inputted
004A
CRLS
Controller lower stroke limit signal being inputted
8000
RD
Ready
DO
8001
SA
Speed reached
8002
ZSP
Zero speed detection
8003
TLC
Limiting torque
8004
VLC
Limiting speed
8005
INP
In-position completion
8007
WNG
Warning
8008
ALM
Malfunction
8009
OP
Z-phase output
800A
MBR
Electromagnetic brake interlock
800B
DB
External dynamic brake
800F
BWNG
Battery warning
8010
ALM2
Malfunction 2
8013
RDY
During ready-on
8015
STO
During STO
8016
SMPD
Magnetic pole detection completion
8017
ZPASS
Z-phase already passed
8018
CDPS2
Variable gain selection 2
8019
CDPS
Variable gain selection
801B
ABSV
Absolute position erased
801D
IPF
Instantaneous power failure
801E
SPC
Under proportional control
801F
MTTR
During tough drive
8032
DOG
During DOG signal input
8049
ZP2
Homing completion 2