(3) Error display and trouble locating
1. Display details
After conducting the self-check referring to 5-2(1),
flashes repetitively and the error code is displayed. The tens
place and ones place of the error code is displayed separately.
When two or more errors occur, they are displayed alternately. The error of which code has smaller number has priority
to be displayed first. There are 0.5 seconds intervals between the error codes.
(2) Timing in self-check
Trouble of Defrost heater
: Self-check is conducted after defrosting.
(Make sure to check the display before unplugging the power cord because it is
automatically reset once the power cord is unplugged.)
Trouble of Ice maker
: Touch
for 5 seconds to operate the automatic ice maker.
All the "
", "
", and " " indicators blink when operation is being checked during the test
operation.
Trouble of Fan motor
: Open the door and then close it.
When any abnormality is found in fan motor, the alarm sounds every time the door is closed.
Trouble of Inverter
: Check the error when the compressor starts up or is operating.
Trouble of Thermistor
: Self-check is continuously working.
For 2 minutes in self-check, a high-tone sound is heard due to the operation check of damper.
2. Check point and corrective measures
e.g.) The errors of refrigerator thermistor (
E13
) and ice maker gear box
(
E33
) are occurring simultaneously.
Tens place
Ones place
Error code
0.5
sec.
0.5
sec.
0.5
sec.
5sec.
E13
E33
E13
E33
5sec.
5sec.
5sec.
b) Tens place of the error code
Display
Corresponding
values
8
4
2
1
b) Tens place
of the error code
c) Ones place
of
the
error
code
Flashing
c) Ones place of the error code
Display
Corresponding
values
8
4
2
1
Display
Error
code
Display
Trouble
Detecting method
(*3)
Check point
Corrective
measures
Control
Tens place Ones place
Self-check
Testing (*1)
Ice maker is under testing
Error display
E 01
(*4)
Communication
error of
operation panel
The following commu-
nication errors occur
between control board
and operation P.C. board:
• They transmit and receive
data that is unrelated to
the settings.
• They cannot transmit
and receive data for
about 10 seconds.
1. Connector CN9S on control board
6-pin wire to wire connector (hinge)
6-pin connector on operation P.C. board
Repair the
contact failure.
The same operation as
that before the communi-
cation error has occurred
is continued.
2. Trouble of control board or operation P.C.
board
Replace.
E 02
Communication
error of inverter
A commutation error occurs
between refrigerator control
circuit and inverter control
circuit in control board. (They
do not transmit and receive
data for 10 seconds.)
Replace the
control board.
Compressor turns OFF.
E 03
Trouble of
model judge-
ment
The model of control
board is different from
that of operation P.C.
board.
1. Check the model name of control board. Replace.
The operation continues.
The error code is displayed.
2. Check the operation P.C. board.
Replace.
E 11
Trouble of
freezer com-
partment
thermistor
There is a short or open
circuit in the freezer
compartment thermistor.
1. Connector CN9S on control board,
6-pin wire to wire connector
Repair the
contact failure.
After the compressor turns
OFF for 10 minutes, it turns
ON for 30 minutes and OFF
for 20 minutes repeatedly.
2. Check the resistance of thermistor.
Replace.
E 12
Trouble of
defrost
thermistor
There is a short or open
circuit in the defrost ther-
mistor.
1. Connector CN9S on control board,
4-pin wire to wire connector
Repair the
contact failure.
The defrost heater is disa-
bled.
2. Check the resistance of thermistor.
Replace.
OAH162