En-3
Indoor unit
Wall hole
sleeve (C)
Cut off the
extra length.
Pipe attachment
strap (E)
Use the wall hole
sleeve (C) to
prevent indoor/
outdoor connect
-
ing wire (A) from
contacting metal
parts in the wall
and to protect
the wiring from
rodents.
Wall hole cover (D)
Seal the wall hole
gap with putty (H).
Attach the pipe
to wall with pipe at
-
tachment strap (E).
Attachment screw (F)
1-4. INSTALLATION DIAGRAM
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1) Drain hose *1
1
(2) Remote controller holder
1
(3) Screws for (2) 3.5 × 16 mm (Black)
2
(4) Pipe cover
1
(5) Band
2
(6) Battery (AAA) for (12)
2
(7) Indoor unit mounting bracket
1
(8) Fixing screws for (7) 4 × 25 mm
5
(9) Wood screw for indoor unit fixation
4
(10) Washer of (9)
4
(11) Felt tape (For left or left-rear piping)
1
(12) Wireless remote controller
1
Note:
*1 The Drain hose is connected to the unit.
FIELD-SUPPLIED PARTS
(A) Indoor/outdoor unit connecting wire *2
1
(B) Extension pipe
1
(C) Wall hole sleeve
1
(D) Wall hole cover
1
(E) Pipe fixing band
2 to 5
(F) Fixing screw for (E) 4 × 20 mm
2 to 5
(G) Piping tape
1
(H) Putty
1
(J)
Drain hose
(or soft PVC hose, 19/32 in. (15 mm) in
-
ner diameter or hard PVC pipe VP16)
1
(K) Refrigeration oil
1
(L) Power supply cord *2
1
Note:
*2 Place indoor/outdoor unit connecting wire (A)
and power supply cord (L) at least 3 ft. (1 m)
away from the TV antenna wire.
Units should be installed by licensed contractor
according to local code requirements.
After the leak test, apply
insulating material tightly so
that there is no gap.
When the piping is to be at
-
tached to a wall comprised of
tin plate or metal netting, use
chemically treated wooden
piece 25/32 in. (20 mm) or
thicker between the wall and
the piping, or wrap insulation
vinyl tape 7 to 8 turns around
the piping.
To use existing piping, per
-
form COOL operation for
30 minutes and pump down
before removing the old air
conditioner. Remake flare
according to the dimension
for new refrigerant.
(L)
(J)
4 in. (100
mm)
or more
14 in.
(350
mm)
or more
8 in.
(200
mm)
*4
or more
4 in.
(100
mm)
or more
Unit: inch
Unit: mm
31-1/2
19-11/16
Air inlet
Air outlet
13-9/16 11-1/4
2-3/8
×
13/16
slot
12~12-3/4
1-9/16
800
500
Air inlet
Air outlet
2-10
×
21 slot
344.5
285
150
40
304~325
5-15/16
<KJ09/12>
<KJ15/18>
(J)
(L)
Unit: inch
Unit: mm
4 in. (100
mm)
or more
4 in.
(100
mm)
or more
14 in.
(350
mm)
or more
20 in.
(500
mm)
*6
or more
Drain piping for outdoor unit
Install the unit horizontally.
Do not use drain socket in cold regions. Drain may freeze and make the fan stop.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unit and/or the grounds from
being wet by drain water or damaged by frozen drain water.
33-1/16
13-3/4~14-5/8
19-11/16
Air inlet
Air
inlet
Air
inlet
Air
inlet
Air
inlet
6-7/8
15-3/8
13
Air outlet
2-3/8 x 13/16 slot
1-9/16
40
840
175
500
Air inlet
390
330
349~371
Air outlet
2-10 x 21 slot
clear
*3
*3 4 in. (100 mm) or more when front
and sides of unit are clear
*4 When any 2 sides of left, right and
rear of unit are clear
clear
*5
*5 20 in. (500 mm) or more when front
and sides of unit are clear
*6 When any 2 sides of left, right and
rear of unit are clear
Obstacles above
It’s possible to
install an obstacle
to the following
area.
6
in.
(150
mm)
or
below
from
the
floor
4 in. (100
mm)
or more
No
obstruction
4 in. (100
mm)
or more
1-37/64 in.
(40 mm) or
less
30° or less
1-49/64
in.
(45
mm)
or
more
JG79Y071H02_en.indd 3
2016/01/21 13:20:00