44
4 STARTUP
4
STARTUP
• MR-J5-_A_ servo amplifiers can be set with MR Configurator2 with software version 1.100E or later.
• This chapter explains how to start up the servo amplifier by using MR Configurator2 with software version
1.100E.
• Before starting operation, check each servo parameter. Depending on the machine, an unexpected
operation may occur.
When using a linear servo motor, the terms below have the following meanings.
• Load to motor inertia ratio
→
Load to motor mass ratio
• Torque
→
Thrust
Servo parameter setting method
MR Configurator2 is the software used for purposes such as servo parameter settings, graph measurement/display, and test
operation. This chapter describes the startup procedure of the servo amplifier when the servo amplifier is connected to a
personal computer which has MR Configurator2 installed. To learn more about using MR Configurator2, refer to Help in MR
Configurator2.
1.
Connect the servo amplifier and the personal computer with a USB cable. Turn on the servo amplifier control circuit
power supply.
2.
Start MR Configurator2 and create a new project. For the connection setting, select USB. Select a servo amplifier model
and an operation mode.
CN5
Servo amplifier
Personal computer
To USB
connector
USB cable
MR-J3USBCBL3M
(option)