3 STRUCTURE
3.2 Switch setting and display of the servo amplifier
31
3
Number of tough
drive operations
times
The number of times the tough
drive function has activated is
displayed.
Unit power
consumption 1
(increment of 1 W)
W
The unit power consumption by
increment of 1 W is displayed. The
positive value indicates power
running, and negative value
indicates regeneration.
The values in excess of ±99999 can
be counted. However, the counter
shows only the lower five digits of
the actual value because the servo
amplifier display is five digits.
Unit power
consumption 2
(increment of 1 kW)
kW
The unit power consumption by
increment of 1 kW is displayed. The
positive value indicates power
running, and negative value
indicates regeneration.
Unit total power
consumption 1
(increment of 1 Wh)
Wh
The unit total power consumption
by increment of 1 Wh is displayed.
The positive value is accumulated
during power running, while
negative value is accumulated
during regeneration.
The values in excess of ±99999 can
be counted. However, the counter
shows only the lower five digits of
the actual value because the servo
amplifier display is five digits.
Unit total power
consumption 2
(increment of 100
kWh)
100 kWh
The unit total power consumption
by increment of 100 kWh is
displayed. The positive value is
accumulated during power running,
while negative value is accumulated
during regeneration.
Cumulative
feedback pulses
from load-side
encoder
pulse
The feedback pulses from the load-
side encoder are counted and
displayed.
The values in excess of ±99999 can
be counted. However, the counter
shows only the lower five digits of
the actual value because the servo
amplifier display is five digits.
Press the "SET" button to reset the
display value to "0".
The decimal points in the upper four
digits are lit for a negative value.
Load-side encoder
droop pulses
pulse
Droop pulses in the deviation
counter, which are the pulse
differences between a load-side
position and a command, are
displayed. When the count exceeds
±99999, it starts from 0.
The decimal points in the upper four
digits are lit for a negative value.
Status display
Symbol
Unit
Description
Control
mode
*1
Operation
mode
*2
P
S
T
Semi
closed
Fully
closed