6. MODBUS REGISTERS
6 - 6
Address
Name and function
Data
type
Read/
write
Initial value
Range
Unit
Saved
to EEP-
ROM
Para-
meter
No. of
Points/
No. of
Registers
Continuous
read/
continuous
write
2B8E Load to motor inertia ratio at alarm occurrence
(Alarm Monitor 14 Load to motor inertia ratio)
The load to motor inertia ratio at alarm
occurrence is returned.
2
bytes
Reading 0000h
to
FFFFh
0.01
times
1
Possible
2B8F Bus voltage at alarm occurrence (Alarm
Monitor 15 Bus voltage)
The bus voltage at alarm occurrence is
returned.
2
bytes
Reading 0000h
to
FFFFh
V 1
Possible
2B96 F/B cumulative value of A/B-phase output pulse
at alarm occurrence (Alarm Monitor 22
Cumulative encoder out pulses)
The feedback cumulative value of A/B-phase
output pulse at alarm occurrence is returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
pulse 2
Possible
2BA5 Internal temperature of encoder at alarm
occurrence (Alarm Monitor 37 Internal
temperature of encoder)
The internal temperature of encoder at alarm
occurrence is returned.
2
bytes
Reading 8000h
to
7FFFh
°C 1
Possible
2BA6 Settling time at alarm occurrence (Alarm
Monitor 38 Settling time)
The settling time at alarm occurrence is
returned.
2
bytes
Reading 8000h
to
7FFFh
ms 1
Possible
2BA7 Oscillation detection frequency at alarm
occurrence (Alarm Monitor 39 Oscillation
detection frequency)
The oscillation detection frequency at alarm
occurrence is returned.
2
bytes
Reading 8000h
to
7FFFh
Hz 1
Possible
2BA8 Number of tough drive operations at alarm
occurrence (Alarm Monitor 40 Number of
tough drive operations)
The number of tough drive operations at alarm
occurrence is returned.
2
bytes
Reading 0000h
to
FFFFh
times 1
Possible
2BAA Internal temperature of amplifier at alarm
occurrence (Alarm Monitor 42 Internal
temperature of amplifier)
The internal temperature of amplifier at alarm
occurrence is returned.
2
bytes
Reading 8000h
to
7FFFh
°C 1
Possible
2BAD Unit power consumption at alarm occurrence
(Alarm Monitor 45 Unit power consumption)
The unit power consumption at alarm
occurrence is returned.
2
bytes
Reading 8000h
to
7FFFh
W 1
Possible
2BAE Unit total power consumption at alarm
occurrence (Alarm Monitor 46 Unit total power
consumption)
The unit total power consumption at alarm
occurrence is returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
Wh 2
Possible
2BAF Current position at alarm occurrence (Alarm
Monitor 47 Current position)
The current position at alarm occurrence is
returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
2
Possible
2BB0 Command position at alarm occurrence (Alarm
Monitor 48 Command position)
The command position at alarm occurrence is
returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
2
Possible
2BB1 Command remaining distance at alarm
occurrence (Alarm Monitor 49 Command
remaining distance)
The command remaining distance at alarm
occurrence is returned.
4
bytes
Reading 80000000h
to
7FFFFFFFh
2
Possible
2C10 External input pin status (External Input pin
display)
The number of entries in external input pin
status is returned.
1
bytes
Reading 1 01h
(fixed)
3
Impossible
External input pin status 1 (External Input pin
display1)
The external input pin status is returned.
4
bytes
Reading 00000000h
to
FFFFFFFFh
Summary of Contents for MELSERVO-JE MR-JE-C