www.dadehpardazan.ir 88594014-15
12 - 26
12. OPTIONS AND AUXILIARY EQUIPMENT
(2) Wires for cables
When fabricating a cable, use the wire models given in the following table or equivalent:
Table 12.2 Wires for option cables
Characteristics of one core
Type
Model
Length
[m(ft)]
Core size
[mm
2
]
Number
of Cores
Structure
[Wires/mm]
Conductor
resistance[ /mm]
Insulation coating
ODd[mm] (Note 1)
(Note 3)
Finishing
OD [mm]
Wire model
2 to 10
(6.56 to 32.8)
0.08
12
(6 pairs)
7/0.127
222
0.38
5.6
UL20276 AWG#28
6pair (BLACK)
MR-JCCBL M-L
20 30
(65.6 98.4)
0.3
12
(6 pairs)
12/0.18
62
1.2
8.2
UL20276 AWG#22
6pair (BLACK)
2 5
(6.56 16.4)
0.2
12
(6 pairs)
40/0.08
105
0.88
7.2
(Note 2)
A14B2343 6P
MR-JCCBL M-H
10 to 50
(32.8 to 164)
0.2
14
(7 pairs)
40/0.08
105
0.88
8.0
(Note 2)
A14B0238 7P
Encoder cable
MR-JC4CBL M-H
30 to 50
(98.4 to 164)
0.2
14
(7 pairs)
40/0.08
105
0.88
8.0
(Note 2)
A14B0238 7P
Communication
cable
MR-CPCATCBL3M
3 (9.84)
0.08
6
(3 pairs)
7/0.127
222
0.38
4.6
UL20276 AWG#28
3pair (BLACK)
MR-J2HBUS M
MR-J2HBUS M-A
20
(10 pairs)
UL20276 AWG#28
10pair (CREAM)
Q172J2BCBL M
Bus cable
Q173J2B CBL M
0.5 to 5
(1.64 to 16.4)
0.08
14
(7 pairs)
7/0.127
222
0.38
6.1
UL20276 AWG#28
7pair (CREAM)
Battery unit
cable
MR-J2MBATCBL
M
0.3 1
(0.98 3.28)
0.3
2
(1 pairs)
12/0.18
63
1.5
5.1
MVVS IP 0.3mm
2
Note 1. d is as shown below:
d
Conductor Insulation sheath
2. Purchased from Toa Electric Industry
3. Standard OD. Max. OD is about 10% greater.
12.2.2 No-fuse breakers, fuses, magnetic contactors
Always use one no-fuse breaker and one magnetic contactor with one drive unit. Make selection as
indicated below according to the total output value of the servo motors connected to one base unit. When
using a fuse instead of the no-fuse breaker, use the one having the specifications given in this section.
(1) No-fuse breaker
Servo motor output total
No-fuse breaker
Rated current [A]
550W max.
30A frame5A
5
More than 550W to 1100W max.
30A frame10A
10
More than 1100W to 1650W max.
30A frame15A
15
More than 1650W to 2200W max.
30A frame20A
20
More than 2200W to 3300W max.
30A frame30A
30
(2) Fuse
Fuse
Servo motor output total
Class
Current [A]
Voltage [V]
800W max.
K5
15
AC250
More than 800W to 1100W max.
K5
20
AC250
More than 1100W to 1650W max.
K5
30
AC250
More than 1650W to 2200W max.
K5
40
AC250
More than 2200W to 3300W max.
K5
70
AC250
(3) Magnetic contactor
Servo motor output total
Magnetic contactor
1700W max.
S-N10
More than 1700W to 2800W max.
S-N18
More than 2800W to 3300W max.
S-N20
Summary of Contents for MELSERVO-J2M series
Page 26: ...www dadehpardazan ir 88594014 15 1 10 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 36: ...www dadehpardazan ir 88594014 15 2 10 2 INSTALLATION AND START UP MEMO ...
Page 64: ...www dadehpardazan ir 88594014 15 3 28 3 SIGNALS AND WIRING MEMO ...
Page 74: ...www dadehpardazan ir 88594014 15 4 10 4 OPERATION AND DISPLAY MEMO ...
Page 112: ...www dadehpardazan ir 88594014 15 6 12 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 122: ...www dadehpardazan ir 88594014 15 7 10 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 124: ...www dadehpardazan ir 88594014 15 8 2 8 INSPECTION MEMO ...
Page 186: ...www dadehpardazan ir 88594014 15 12 36 12 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Page 190: ...www dadehpardazan ir 88594014 15 13 4 13 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...