36
7 APPENDIX
7.1 Combination with EMC filters
Combination with converter units and drive units of 30 kW or
more
MR-J3 series
*1 To use this EMC filter, a surge protector is required.
Page 37 Details of surge protector
MR-J2-Super series
*1 To use this EMC filter, a surge protector is required.
Page 37 Details of surge protector
Converter
unit
Drive unit
Recommended filter (Soshin Electric)
Mass [kg]
Model
Rated current
[A]
Rated voltage
[VAC]
Leakage
current [mA]
MR-J3-CR55K
MR-J3-DU30K_/MR-J3-DU37K_
HF3200A-UN
200
250
9
18
MR-J3-
CR55K4
MR-J3-DU30K_4 to MR-J3-
DU55K_4
TF3150C-TX
150
500
5.5
31
Converter
unit
Servo amplifier
Recommended filter (Soshin Electric)
Mass [kg]
Model
Rated current
[A]
Rated voltage
[VAC]
Leakage
current [mA]
MR-HP30KA
MR-J2S-30K_/MR-J2S-37K_
HF3200A-TMA
200
250
3
23.5
MR-HP55KA4
MR-J2S-30K_4 to MR-J2S-45K_4
TF3150C-TX
150
500
5.5
31