48
2 SPECIFICATIONS
2.2 Sensor Head Specifications
350mm type (Class 2)
For measuring conditions not specified, refer to the following.
Page 39 Product specification notes
*1 Use the ND filter in case the amount of reflected beam is too large.
*2 The measurement range is limited between 0.0 and 50mm (in case the sampling cycle is 20
s at diffuse reflection), between 0.0 and
42mm (in case the sampling cycle is 20
s at specular reflection), between 36 and 50mm (in case the sampling cycle is 10
s at diffuse
reflection), or between 36 and 42mm (in case the sampling cycle is 10
s at specular reflection).
*3 The figure shows the value at measurement center distance. It is determined by 1/e
2
(approximately 13.5%) of center beam intensity.
Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may
affect the measurement value.
*4 The variation in ambient illuminance is
0.03% F.S. or less.
*5 Terminate a laser beam using a diffusely reflecting material or by an absorber regardless of the safety distance.
Item
MH11H35B0SNA
MH11H35B0LNA
Diffuse reflection
Specular reflection
Diffuse reflection
Specular reflection
Measurement method
Diffuse reflection/specular reflection
Measurement center distance
350mm
348mm
350mm
348mm
Measurement range
50mm
42mm
50mm
42mm
Beam source
Red semiconductor laser, Class 2 (JIS/IEC/GB/FDA)
Max output: 1mW, Emission peak wavelength: 658nm
Beam diameter
Approx.
250
m
Approx. 250
3500
m
Light receiving element
Linear image sensor
Resolution
2.0
m/average times: 256, 0.5
m/average times: 4096
Linearity
0.03% F.S.
Temperature characteristics
0.01% F.S./
Safety distance (Normal ocular hazard
distance: NOHD)
1.4m
Indicator
Laser radiation
indicator
Green light-emitting diode
ON during laser radiation
Measurement range
indicator
Yellow light-emitting diode
ON near the measurement center/Flashes within the measurement range/OFF outside the measurement range
Protective structure
IP67 (excluding the connector part)
Pollution degree
2
Insulation resistance
With 500VDC megger, 20M
or more (between all the terminals and case)
Withstand
voltage
Commercial
frequency
500VAC, 1 minute (between all the terminals and case)
Impulse
1000V, 1.2/50
s (between all the terminals and case)
Vibration resistance
Endurance: 10 to 55Hz (cycle: 1 minute), double amplitude: 1.5mm
X, Y, Z directions, 2 hours each
Shock resistance
196m/
X, Y, Z directions, 3 times each
Ambient illuminance
3000lx or less
(illuminance at light receiving surface using incandescent lamp)
Operating ambient temperature
0 to 45
(No dew condensation or icing allowed)
At storage: -20 to 70
Operating ambient humidity
35 to 85%RH
At storage: 35 to 85%RH
Operating altitude
0 to 2000m
Material
Main body case, main body cover: Die-cast aluminum
Front cover: Glass
Cable length
0.5m
Cable extension
The cable length can be extended to full length of 30m with the extension cable for sensor head.
Weight
Approx. 450g (including the sensor head cable)