3) Control sequence
(1) A command is sent from the computer to the monitor. (Commands should be sent at intervals of at least 600 ms.)
(2) The monitor sends a return command within 600 ms* after receiving the end code. If the monitor fails to receive the
command, it doesn’t send any return command. (*During the power-on/off or input selection process, the transmission of the
return command may take more than 600 ms.)
(3) The computer checks the return command to see whether the command it sent was received or not. The computer must
receive the return command before sending the next command.
(4) The monitor sends various codes other than commands including the return command. While RS-232C control sequence is
in progress, the computer must reject the codes.
Example: Turn the power ON (‘ ’ is for ASCII code)
Control command from
computer
Return command from
monitor to computer
Description of command
30 30 21 0D
‘0’ ‘0’ ‘!’ ‘
’
Sending a command for
power-on
30 30 21 0D
‘0’ ‘0’ ‘!’ ‘
’
Command received
(Command echoed back)
4) Operation commands
The operation commands confi gure the basic operation settings of this LCD monitor. The commands may not work during signal
switchover.
The operation commands have no data codes.
Operation
ASCII
HEX
POWER ON
!
21h
POWER OFF
"
22h
Turn off the power forcefully.*
""
22h 22h
INPUT RGB 1
_r1
5Fh 72h 31h
INPUT RGB 2
_r2
5Fh 72h 32h
INPUT RGB 3
_r3
5Fh 72h 33h
INPUT RGB 4
_r4
5Fh 72h 34h
INPUT OPTION**
_r5
5Fh 72h 35h
INPUT RGB 6
_r6
5Fh 72h 36h
INPUT VIDEO
_v1
5Fh 76h 31h
INPUT DVD/HD
_v2
5Fh 76h 32h
INPUT S-VIDEO
_v3
5Fh 76h 33h
VOLUME UP
r06
72h 30h 36h
VOLUME DOWN
r07
72h 30h 37h
MUTE
ra6
72h 61h 36h
AUTO SETUP
r09
72h 30h 39h
• When you send the POWER ON or POWER OFF command, send the next command at intervals of at least 14 seconds.
• It is recommended that after sending a command for video input selection, wait for at least 5 seconds to send the next
command. Otherwise, the monitor may not reply within 600 ms.
• In the power off mode or the sleep mode, only the POWER ON, POWER OFF, and POWER ON read commands which are
described on the next page can be operated.
* Used when the OPS-compliant computer makes no response.
** OPTION can be used when an extension module is mounted on the option slot.