22
Indication
Error code
A5
A8
Error item
Key lock
EEPROM error
Cause and remedy
A
key has been pressed for 15 seconds or longer
.
EEPROM failure
Part name
Gas circuit board, LED circuit board
Power supply control circuit board
Condition
—
—
Connector
—
—
T
erminal to check
—
—
Normal value
—
—
Indication
Error code
E0
E9
Error item
Human sensing unit failure
Automatic rotation turntable malfunction
Cause and remedy
Cause:
An error has occurred in communication with the human sensing unit.
Remedy: Check that the connector P21
1 is inserted properly
.
Cause:
After the automatic rotation turntable operated, the target position has not been
reached after 100 seconds has past.
Remedy: Check that the relay connectors P203 and P214 are inserted properly
.
Part name
Human sensing unit
—
Condition
—
—
Connector
P21
1
—
T
erminal to check
—
—
Normal value
—
—