Multi-ventilation Mode enables the appropriate supply/
exhaust balance to be selected to suit the usage environment and location

Featuring "Multi-ventilation Mode," 
which allows the air supply/exhaust 
balance to be varied dynamically. 
The supply/exhaust balance can be 
selected to suit the usage environment 
and location, such as allowing for air 
exhausted via extractor fans. Modes can 
be selected easily by setting the 
connectors on the circuit board.

* "High notch" can also be further set to "Extra High" using the unit switch.

Offers choice of 9 air supply/exhaust combination patterns.

Hand-held remote control
 for microprocessor type

Supply airflow

High

High

Low

Low

Exhaust airflow

High

Low

High

Low

Air supply and exhaust are "Low"
irrespective of unit setting.

Unit setting

* Factory setting is "High" for 
   both supply and exhaust.

Air supply

High

High

Low

Air exhaust

High

Low

High

Ventilation mode

Power air supply/exhaust mode

Power air supply mode

Power air exhaust mode

Energy-saving ventilation mode

Low

High

Control switch

Smaller offices or
tenant buildings, etc.

Using LOSSNAY compensates 
for using extractor fans...

Power air supply

Smoking areas, etc.

Priority on air exhaust...

Power air exhaust

Normal office, etc.

Providing efficient ventilation 
while maintaining air 
supply/exhaust balance...

Power air supply

/exhaust

Energy Saving by 

Energy Saving by 

Night Purge Function

Newly Adopted Dot Matrix Display Available in Eight Languages

During the summer season, the Night Purge function draws cooler outside air into the room to suppress temperature 
rises at night. This energy conservation function reduces the load when air conditioning is started the next morning.

timer

The out door temperture (OA) setting can be selected either 17

 

C or 28

 

C by using Dip-Switch (SW2-7) in the LOSSNAY control box. Refer to the Instillation Manual for more information.

*Do not use the night purge function if fog and heavy rain is expected. The entry of rain water may occur in the night.

While air conditioning and 

ventilation are not operating, 

the room temperature rises as 

a result of heat from the 

skeleton and OA equipment.

When the outside temperature 

becomes lower than the room 

temperature, ventilation starts 

automatically.

The air conditioning load 

required to reach the set 

temperature the next 

morning is reduced.

At night, the outside 

temperature drops.

When the room becomes 

sufficiently cool, ventilation 

is stopped.

Hot air is discharged.

Example B (Weekly)

Example A (Hourly)

8:00

9:00

12:00

13:00

17:00

19:00

22:00

low

high

low

high

low

extra low

new RX

5

 series with PZ-60DR-E

8:00

high

current RX

4

 series with PZ-41SLB controller

22:00 

New Remote Controller PZ-60DR-E

A new remote controller for the RX5 series is now available. In addition to boosting the energy conservation performance of 
the main unit, the remote controller features a variety of new functions which also pursue additional energy conservation.
The appearance of the remote controller conforms to Mitsubishi air conditioner interface design standards.
Functions that were set using Dip-Switch on the LOSSNAY main unit can now be configured as needed using the new re-
mote controller. This eliminates the need to crawl under the eaves to change operation settings.
Also, a newly adopted dot matrix display provides much more information, making it easy to check maintenance indica-
tions, operation status display, and explanations required when configuring settings.

Tolal power consumption in one day : LGH-100RX

4

-E : 6,600W (14 hours)

 

        

                                                 LGH-100RX

5

-E : 5,390W (14 hours)   

1,210W (18%) less

8:00

9:00

12:00

13:00

17:00

19:00

22:00

low

high

low

high

low

extra low

Monday

to

Thursday

8:00

9:00

12:00

13:00

17:00

22:00

low

high

low

high

extra low

Friday

extra low

8:00

22:00

Saturday

to

Sunday

VENTILATION

ENGLISH

Geblasebetrieb

Deutsch

VENTILATION

FRENCH

ESPANOL

ARIAESTERNA

ITALIANO

Air volume level can be set hourly (max 8 
times) and weekly. You can pre-set air 
volume according to the predictable 
requirement so that LOSSNAY can 
automatically operate at only necessary 
air-speed at the specified time period, 
which saves power consumption while 
maintaining the indoor air quality.
Besides, once the weekly timer has been 
set, no switching on-off is required.

Dot matrix display

 

 Button

Filter button

"Extra Low" fan speed button 
OPERATION button 

 ON/OFF button

 

Function selector button

 

Set time buttons   Back   Ahead

 OPERATION buttons 

 Back   Ahead

Fan speed Adjustment button 

 CLEAR button 

Timer ON/OFF (DAY) button

Timer MENU (MONITOR/SET) button

 Return button

VENTILACIoN

e

Summary of Contents for Lossnay LGH-150RX5-E

Page 1: ...U TOKYO 100 8310 JAPAN http Global MitsubishiElectric com Y08 003 Nov 2008 MEE Specifications subject to change without notice C o n c e n t r a t i n g w h a t w e c a n d o m o r e e v e r a n d d e f i n i t e l y ENERGY RECOVERY VENTILATORS RX5 SERIES MODEL ...

Page 2: ...50 38 5kJ kg DA 33ºC 20 1g kg DA 63 84 6kJ kg DA 26ºC 10 5g kg DA 50 52 9kJ kg DA Energy recovery calculating equation Indoor supply air temperature ºC Indoor temperature ºC Outdoor temperature ºC _ Temp recovery efficiency Outdoor temperature ºC Calculation example 16ºC 20ºC _ 0ºC 80 0ºC Energy recovery calculating equation Indoor supply air temperature ºC Outdoor temperature ºC Indoor temperatur...

Page 3: ...uilding during the cooling season such as early morning or at night By pass ventilation will draw in the cooler outside air and reduce the cooling load on the system 2 Night purge By pass ventilation can be used to release hot air from inside the building that has accumulated in buildings a business district during the hot summer season 3 Office equipment room cooling During cold season fresh air ...

Page 4: ...er than the room temperature ventilation starts automatically The air conditioning load required to reach the set temperature the next morning is reduced At night the outside temperature drops When the room becomes sufficiently cool ventilation is stopped Hot air is discharged Example B Weekly Example A Hourly 8 00 9 00 12 00 13 00 17 00 19 00 22 00 low high low high low extra low new RX5 series w...

Page 5: ... units and general equipment To operate general equipment PAC YG66DCA is required Switches between Cool Dry Auto Fan Heat Group of LOSSNAY unit automatic ventilation vent heat interchange normal ventilation depending on the air conditioner unit Auto mode is for City Multi R2 and WR2 series only Cool Dry 19 67 30 87 14 57 30 87 Heat 17 63 28 83 17 63 28 83 Auto 19 67 28 83 17 63 28 83 in case of us...

Page 6: ...olyolefin EU F7 Standard filter High efficiency filter EA OA Lighting etc Replacement components for the standard air filter supplied with the LOSSNAY LGH main unit Model Applicable model PZ 25RF8 E PZ 35RF8 E PZ 50RF8 E PZ 65RF8 E PZ 80RF8 E PZ 100RF8 E LGH 15RX5 E LGH 25RX5 E LGH 35RX5 E LGH 50RX5 E LGH 65RX5 E LGH 80RX5 E LGH 150RX5 E 2sets LGH 100RX5 E LGH 200RX5 E 2sets Filter material Dimens...

Page 7: ... back for more Cleanliness is the key to an attractive atmos phere and restaurants devote significant effort to ensuring the premises are sanitary Sanitation and cleanliness how ever are not enough No matter how clean a restaurant may look if there are bothersome odors lingering in the air all those efforts go to waste and the restaurant s clean image is tarnished For these reasons we invite resta...

Page 8: ...a high Air volume L s O mmH 2 0 30 25 20 15 10 5 Pa m2 h 300 250 50 100 150 200 250 200 150 100 50 0 20m 10m 5m 15m 50Hz Single phase 240V Exchange efficiency External static pressure 50 60 70 80 90 100mm length dia pipe 10 20 30 40 50 60 70 0 High Unit mm LGH 15 to 100RX5 LGH 150 and 200RX5 LGH 15RX5 E Frequency Power source Ventilation mode Fan speed Current A Power consumption W Air volume Mode...

Page 9: ...where duct direction 63 63 65 65 Inspection opening Extra low Extra high Low Temperature exchange efficiency efficiency Cooling Enthalpy exchange efficiency Heating Enthalpy exchange 25 20 0 150 90 80 70 60 50 Exchange efficiency 50Hz Single phase 240V 30m 20m 10m External static pressure 5 10 15 Pa O 2 H m m 100 90 80 70 60 40 50 Air volume L s m2 h length pipe 40m dia 400 50 100 30 150 200 250 3...

Page 10: ...ore air filter High Position where duct direction Inspection opening 208 192 Extra low Temperature exchange efficiency Enthalpyexchange efficiency Heating Enthalpy exchange efficiency Cooling Extra high Low High Unit mm LGH 50RX5 E LGH 65RX5 E Ventilation mode Fan speed Current A Power consumption W Air volume Model External static pressure Temperature exchange efficiency Enthalpy exchange efficie...

Page 11: ...pection opening 258 242 Low efficiency Heating Enthalpy Temperature exchange efficiency Enthalpy exchange efficiency Cooling exchange Extra high Extra low High 50Hz Single phase 240V External static pressure m 2 H m O 10 20 Exchange efficiency 0 m2 h 350 50 100 150 200 250 300 250mm length pipe dia 50 60 70 80 90 Pa 40 30 50 0 500 100 200 300 400 1200 1000 800 600 400 200 0 100m 60m 20m 40m 80m Ai...

Page 12: ...se 240V Pa Enthalpy exchange efficiency Cooling efficiency Heating Enthalpy exchange Temperature exchange efficiency Low High Extra high 90 80 70 60 50 External static pressure Exchange efficiency 0 500 1000 1500 2000 2500 300 200 100 400 500 m2 h 0 700 600 500 400 300 200 100 Air volume L s 10 20 30 40 50 0 2 H m m O Unit mm LGH 150RX5 E LGH 200RX5 E Ventilation mode Fan speed Current A Power con...

Page 13: ... controller Max 2remote controllers installable cable 2nd LOSSNAY unit Up to max 15 units 1 LGH 150RX5 and 200RX5 Definition of Symbols M1 Motor for exhaust fan X10 X11 X12 Relay contact M2 Motor for supply fan X101 X102 X103 Relay Supply fan speed control C Capacitor X201 X202 X203 Relay Exhaust fan speed control GM Motor for By pass operation CN1 Connector Transformer primary LS Microswitch CN2 ...

Page 14: ...nt condensation from forming If it is expected that the ambient temperature around the place where the LOSSNAY unit is installed will be high during the summer air conditioning season it is recommended that the indoor ductwork be covered with insulation material 7 Inspection opening 450 450 or 600 600mm must be installed on the filter and LOSSNAY core removing side LOSSNAY model selection advices ...

Reviews: