![Mitsubishi Electric FX3U-1PG User Manual Download Page 134](http://html.mh-extra.com/html/mitsubishi-electric/fx3u-1pg/fx3u-1pg_user-manual_238960134.webp)
Appendix B: Example Connection
Appendix B-5 Example of Connection with Stepping Motor Driver
128
FX
3U
-1PG User's Manual
Appendix B-5 Example of Connection with Stepping Motor Driver
*1.
The I/O specification of the FX
3U
-1PG is 5 to 24 V DC. However, confirm the voltage range and circuit
configuration of the stepping motor driver before wiring.
For the voltage range and circuit configuration of the FX
3U
-1PG, refer to the following.
→
For the voltage range, refer to Section 2.4 and 2.5.
→
For the circuit configuration, refer to Section 5.1 and 5.2.
L
24V
X000
X001
X002
X003
X004
X005
X006
X007
X010
S/S
DOG
STOP
COM1
CLR
PG0+
PG0-
FP
COM0
RP
STOP
Error reset
Forward limit
Reverse limit
Forward JOG
Reverse JOG
Zero return command
Start
X011
X012
0V
S/S
FX
3U
-1PG
FX
3U
Series
PLC
Stepping motor driver
LSD
STOP
N
VIN
CW+
CW-
AC power supply
Class-D
grounding
Cable length:
2 m or less
Cable length:
2 m or less
Cable length:
2 m or less
Class-D
grounding
Class-D
grounding
Zero-point
sensor
Stepping
motor
DC power supply
*1
DC power
supply
*1
CCW-
CCW+
Class-D
grounding