10. (D) Operation Command and Frequency Command
10.5 JOG operation
10.5
JOG operation
The frequency and acceleration/deceleration time for JOG operation can be set.
JOG operation can be used for conveyor positioning, test operation, etc.
These parameters can be selected from among simple mode parameters when the LCD operation panel (FR-LU08) or the
parameter unit (FR-PU07) is connected to the inverter.
*1
60 Hz is initially set in
Pr.20
in Group 1, and 50 Hz in Group 2. (Refer to
).
JOG operation by inputting signals (JOG signal and JOG2 signal)
• Operation can be started and stopped by the start signals (STF and STR signals) when the Jog operation selection (JOG)
signal or Jog operation selection 2 (JOG2) signal is ON. (For the operation method, refer to
.)
• The JOG signal can be input only via a control terminal. For the JOG signal, set "5" to any parameter from
Pr.178 to Pr.184
(Input terminal function selection)
to assign the function to a control terminal.
• The JOG2 signal can be input via a control terminal or via communication. For the JOG2 signal, set "30" to any parameter
from
Pr.178 to Pr.189 (Input terminal function selection)
to assign the function to a control terminal.
• Use the JOG acceleration/deceleration time function (
Pr.16
) to set the acceleration/deceleration time for JOG operation.
JOG operation using the operation panel
• When the operation panel is in the JOG operation mode, the motor jogs only while a key for start command is pressed.
(For the operation method, refer to
NOTE
• The reference frequency during acceleration/deceleration depends on the
Pr.29 Acceleration/deceleration pattern
selection
setting. (Refer to
.)
• The
Pr.15
setting should be equal to or higher than the
Pr.13 Starting frequency
setting.
• Changing the terminal assignment using
Pr.178 to Pr.189 (Input terminal function selection)
may affect the other functions.
Set parameters after confirming the function of each terminal.
• During JOG operation, the second acceleration/deceleration function using the RT signal is disabled. (Other second functions
are enabled (refer to
• When
Pr.79 Operation mode selection
= "4", JOG operation is started by one push of the RUN key on the operation panel
and stopped by the STOP/RESET key.
• This function is invalid when
Pr.79
= "3".
Parameters referred to
Pr.13 Starting frequency
Pr.
Name
Initial
value
Setting range
Description
15
D200
Jog frequency
5 Hz
0 to 590 Hz
Set the frequency for JOG operation.
16
F002
Jog acceleration/
deceleration time
0.5 s
0 to 3600 s
Set the motor acceleration/deceleration time during JOG operation.
The acceleration/deceleration time is a period of time that the
inverter takes to increase/decrease the output frequency to the
frequency set in
Pr.20 Acceleration/deceleration reference
frequency
The acceleration/deceleration times cannot be set separately.
Output frequency(Hz)
Pr.20
Pr.15
setting range
Pr.16
Forward
rotation
Reverse
rotation
Time
ON
ON
ON
JOG/JOG2 signal
Forward rotation STF
Reverse rotation STR
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...