PARAMETER
128
PID action selection
0, 20, 21,
40 to 43
0
129
PID proportional band
0.1 to 1000 %,
9999
100 %
130
PID integral time
0.1 to 3600 s,
9999
1 s
131
PID upper limit
0 to 100 %,
9999
9999
132
PID lower limit
0 to 100 %,
9999
9999
133
PID action set point
0 to 100 %,
9999
9999
134
PID differential time
0.01 to 10 s, 9999
9999
145
PU display language
selection
0 to 7
1
146
Parameter for manufacturer setting. Do not set.
150
Output current
detection level
0 to 200 %
150 %
151
Output current
detection signal
delay time
0 to 10 s
0 s
152
Zero current
detection level
0 to 200 %
5 %
153
Zero current
detection time
0 to 1 s
0.5 s
156
Stall prevention
operation selection
0 to 31, 100, 101
0
157
OL signal output timer
0 to 25 s, 9999
0 s
158
AM terminal function
selection
1 to 3, 5, 8 to 12,
14, 21, 24, 52, 53,
61, 62
1
160
Extended function
display selection
0, 9999
0
161
Frequency setting/
key lock operation
selection
0, 1, 10, 11
0
162
Automatic restart
after instantaneous
power failure
selection
0, 1, 10, 11
1
165
Stall prevention
operation level
for restart
0 to 200 %
150 %
166
Output current
detection signal
retention time
0 to 10 s,
9999
0.1 s
167
Output current
detection operation
selection
0, 1
0
168
Parameter for manufacturer setting.
Do not set.
169
170
Watt-hour meter clear
0, 10, 9999
9999
171
Operation hour
meter clear
0, 9999
9999
178
STF terminal function
selection
0 to 5, 7, 8, 10, 12,
14, 16, 18, 24, 25,
37, 60, 62, 65 to
67, 9999
60
Parameter Name
Setting Range
Initial Value
179
STR terminal function
selection
0 to 5, 7, 8, 10, 12,
14, 16, 18, 24, 25,
37, 61, 62, 65 to
67, 9999
61
180
RL terminal function
selection
0 to 5, 7, 8, 10, 12,
14, 16, 18, 24, 25,
37, 62, 65 to 67,
9999
0
181
RM terminal function
selection
1
182
RH terminal function
selection
2
190
RUN terminal function
selection
0, 1, 3, 4, 7, 8, 11
to 16, 25, 26, 46,
47, 64, 70, 80, 81,
90, 91, 93, 95, 96,
98, 99, 100, 101,
103, 104, 107,
108, 111 to 116,
125, 126, 146,
147, 164, 170,
180, 181, 190,
191, 193, 195,
196, 198, 199,
9999
0
192
ABC terminal function
selection
0, 1, 3, 4, 7, 8, 11
to 16, 25, 26, 46,
47, 64, 70, 80, 81,
90, 91, 95, 96, 98,
99, 100, 101, 103,
104, 107, 108, 111
to 116, 125, 126,
146, 147, 164,
170, 180, 181,
190, 191, 195,
196, 198, 199,
9999
99
197
SO terminal function
selection
0, 1, 3, 4, 7, 8, 11
to 16, 25, 26, 46,
47, 64, 70, 80, 81,
90, 91, 93, 95, 96,
98, 99, 100, 101,
103, 104, 107,
108, 111 to 116,
125, 126, 146,
147, 164, 170,
180, 181, 190,
191, 193, 195,
196, 198, 199
80
232
to
239
Multi-speed setting
(speeds 8 to 15)
0 to 400 Hz, 9999
9999
240
Soft-PWM operation
selection
0, 1
1
241
Analog input display
unit switchover
0, 1
0
244
Cooling fan operation
selection
0, 1
1
245
Rated slip
0 to 50 %, 9999
9999
246
Slip compensation
time constant
0.01 to 10 s
0.5 s
247
Constant-power range
slip compensation
selection
0, 9999
9999
249
Earth (ground) fault
detection at start
0, 1
0
250
Stop selection
0 to 100 s,
1000 to 1100 s,
8888, 9999
9999
251
Output phase loss
protection selection
0, 1
1
255
Life alarm status
display
(0 to 15)
0
256
Inrush current
suppression circuit life
display
(0 to 100 %)
100 %
Parameter Name
Setting Range
Initial Value