17
2
2.5 Encoder cables dedicated to Mitsubishi motors
Use dedicated encoder cables to connect with Mitsubishi encoder-equipped motors.
As the terminal block of the FR-A8AP is an insertion type, earth (ground) cables need to be modified. (Refer to
.)
FR-JCBL
FR-V7CBL
For SF-JR/HR/JRCA/HRCA (with encoder)
For SF-V5RU and SF-THY
Encoder
Positioning keyway
PZ2
PZ1
PB2
PB1
PA2
PA1
PG
SD
P
B
N
A
R
C
H
K
2mm
2
A B
C
D
E
K
F
G
H
J
L
M
S
N
R
P
T
D/MS3106B20-29S
(As viewed from wiring side)
FR-A800
(FR-A8AP)
F-DPEVSB 12P 0.2mm
2
Earth cable
Approx. 140 mm
60mm
L
D/MS3057-12A
D/MS3106B20-29S
11
m
m
Type
Length
L (m)
FR-JCBL5
5
FR-JCBL15
15
FR-JCBL30
30
Encoder
Positioning keyway
PZ2
PZ1
PB2
PB1
PA2
PA1
SD
PG
G
F
D
C
B
A
R
S
2mm
2
FR-A800
(FR-A8AP)
A
B
C
D
E
K
F
G
H
J
L
M
S
N
R
P
T
D/MS3106B20-29S
(As viewed from wiring side)
Earth cable
F-DPEVSB 12P 0.2 mm
2
L
D/MS3106B20-29S
D/MS3057-12A
11
m
m
60mm
Approx. 140 mm
Type
Length
L (m)
FR-V7CBL5
5
FR-V7CBL15
15
FR-V7CBL30
30
• A P clip for earthing (grounding) a
shielded cable is provided.
A8AP.book 17 ページ 2013年9月12日 木曜日 午後7時48分