41
BASIC OPERATION
1008
Clock (hour, minute)
0 to 59,
100 to 159,
200 to 259,
300 to 359,
400 to 459,
500 to 559,
600 to 659,
700 to 759,
800 to 859,
900 to 959,
1000 to 1059,
1100 to 1159,
1200 to 1259,
1300 to 1359,
1400 to 1459,
1500 to 1559,
1600 to 1659,
1700 to 1759,
1800 to 1859,
1900 to 1959,
2000 to 2059,
2100 to 2159,
2200 to 2259,
2300 to 2359
0
1015
Integral stop selection
at limited manipulated
amount
0, 1
0
1016
PTC thermistor
protection detection
time
0 to 60 s
0 s
1018
Monitor with sign
selection
0, 9999
9999
1020
Trace operation
selection
0 to 4
0
1021
Trace mode selection
0 to 2
0
1022
Sampling cycle
0 to 9
2
1023
Number of analog
channels
1 to 8
4
1024
Sampling auto start
0, 1
0
1025
Trigger mode
selection
0 to 4
0
1026
Number of sampling
before trigger
0 to 100%
90%
1027
Analog source
selection (1ch)
1 to 3, 5 to 14,
17 to 20,
22 to 24,
26 to 36,
40 to 42, 46,
52 to 54, 61 to 64,
67, 71 to 74,
81 to 93, 97, 98,
201 to 213,
230 to 232,
235 to 238
201
1028
Analog source
selection (2ch)
202
1029
Analog source
selection (3ch)
203
1030
Analog source
selection (4ch)
204
1031
Analog source
selection (5ch)
205
1032
Analog source
selection (6ch)
206
1033
Analog source
selection (7ch)
207
1034
Analog source
selection (8ch)
208
1035
Analog trigger
channel
1 to 8
1
1036
Analog trigger
operation selection
0, 1
0
1037
Analog trigger level
600 to 1400
1000
Parameter Name
Setting range
Initial value
1038
Digital source
selection (1ch)
1 to 255
1
1039
Digital source
selection (2ch)
2
1040
Digital source
selection (3ch)
3
1041
Digital source
selection (4ch)
4
1042
Digital source
selection (5ch)
5
1043
Digital source
selection (6ch)
6
1044
Digital source
selection (7ch)
7
1045
Digital source
selection (8ch)
8
1046
Digital trigger channel 1 to 8
1
1047
Digital trigger
operation selection
0, 1
0
1048
Display-off waiting
time
0 to 60 min
0 min
1049
USB host reset
0, 1
0
1072
Tension reverse
selection
0, 1
0
1073
*19
Ethernet
communication
network number
1 to 239
1
1074
*19
Ethernet
communication
station number
1 to 120
1
1075
*19 Link speed and duplex
mode selection
0 to 4
0
1076
*19 Ethernet function
selection 1
502,
5000 to 5002,
5006 to 5008,
5010 to 5013,
9999, 45237,
61450
5001
1077
*19 Ethernet function
selection 2
45237
1078
*19 Ethernet function
selection 3
9999
1103
Deceleration time at
emergency stop
0 to 3600 s
5 s
1106
Torque monitor filter
0 to 5 s, 9999
9999
1107
Running speed
monitor filter
0 to 5 s, 9999
9999
1108
Excitation current
monitor filter
0 to 5 s, 9999
9999
1113
Speed limit method
selection
0 to 2, 10
0
1114
Torque command
reverse selection
0, 1
0
1115
Speed control integral
term clear time
0 to 9998 ms
0 s
1116
Constant output range
speed control P gain
compensation
0 to 100%
0%
1117
Speed control P gain 1
(per-unit system)
0 to 300, 9999
9999
1118
Speed control P gain 2
(per-unit system)
0 to 300, 9999
9999
1119
Model speed control
gain (per-unit system) 0 to 300, 9999
9999
Parameter Name
Setting range
Initial value
*19
Available for the Ethernet models only,