6.Names and Functions of Each Part
6.Names and Functions of Each Part
Energy Measuring Unit
No.
Segment Name
Description
1
Measured value display
Digitally displays measured values.
2
Display of measured items
Displays the measured item for the value displayed
3
Communication display
Only lights up if a logging unit or
communication unit is connected.
4
Energy measurement display
Lights up when measuring electric energy (consumption).
5
Settings display
The icon lights up when in setting mode.
The icon lights up when in setting confirmation mode.
Codes and Functions of Terminal Block
Terminal Code
P1
,
P2
,
P3
Input voltage
Connect the voltage input wire for the measuring circuit.
Frame GND (FG)
Connect to ground (D type ground).
MA
,
MB
Auxiliary power
Connect the auxiliary power supply.
485+
,
485-
MODBUS
®
RTU
communication
Connect the MODBUS
®
RTU communication wire.
SLD
Connect to ground (D type ground).
Ter
1k
,
1L
,
3k
,
3L
Input current
Function
Description
Terminal Code
Function
Description
Codes and Functions of Terminal Block
P1/P1
,
P2/P0
P3/P3
,
NC/F2
Input voltage
Connect the voltage input wire
for the measuring circuit.
Frame GND (FG)
Connect to ground (D type ground).
MA
,
MB
Auxiliary power
Connect the auxiliary power supply.
X1
,
COMX
Pulse
/Contact input
Connect pulse/contact input wires.
Y1
,
COMY
Pulse
/Contact output
Connect pulse/contact output wires.
1k
,
1L
,
2k
,
2L
3k
,
3L
Input current
485+
,
485-
MODBUS
®
RTU
communication
Connect the MODBUS
®
RTU communication wire.
SLD
Connect to ground (D type ground).
Ter
[Standard Model]EMU4-BD1-MB
Logging Unit EMU4-LM
CC-Link Communication Unit EMU4-CM-C
[High Performance Model]EMU4-HD1-MB
Display Screen
Voltage Input Terminal
Frame GND Terminal
Auxiliary Power Terminal
Current Input Terminal
MODBUS Communication Terminal
LCD screen
Operating Switch
MODBUS Communication Terminal
Contact/Pulse Output Terminal
Contact/Pulse Input Terminal
Voltage Input Termina
Frame GND Terminal
Auxiliary Power Terminal
LCD screen
Operating Switch
Current Input Terminal
Names and Functions of Each Part
No.
Function
1)
LOG.LED
Displays logging operation status.
Lit up: Logging is being performed.
Not lit up: Logging operation is stopped.
Slow flashing*
1
(5 sec.): Changing of logging conditions
settings has been completed.
Fast flashing*
2
(30 sec.): Changing of logging conditions
settings has failed.
Fast flashing*
2
: Error has occurred.*
3
2)
SDC.LED
Displays SD memory card communication status.
Lit up: Communication is being performed.
Not lit up: Communication is stopped.
Fast flashing*
2
: SD memory card error*
3
3)
BAT.LED
Displays the battery voltage status
Lit up: Battery voltage is low*
4
.
Not lit up: Battery voltage is normal
6)
Battery connector
Connector for connecting the battery.
7)
IEC rail stopper
Used for fixing to the IEC rail.
8)
Coupling tab
Used for fixing the logging unit.
to the energy measuring unit.
4)
Battery box
Contains the battery for performing backup of current time,
logging and system log data.
5)
SD memory card slot
Slot for inserting the SD memory card
*1: Slow flashing: Lit up for 0.5 sec.
→
Not lit up for 0.5 sec.
→
Lit up for 0.5 sec.
(pattern is repeated)
*2: Fast flashing: Lit up for 0.25 sec.
→
Not lit up for 0.25 sec.
→
Lit up for 0.25 sec.
(pattern is repeated)
*3: If this is lit up, refer to “Error Display and Recovery Procedures” of the “Operation Manual
(Detailed Version)”.
*4: Turning the power off when the battery voltage is low deletes the current time and logging data.
(Set values for logging ID, logging mode, logging start time, detailed data logging cycle and
logging items are not deleted due to being stored in non-volatile memory.) Replace the
battery if BAT. LED lights up.
Name
CC-Link Communication Unit EMU4-CM-C
No.
Name
Function
1)
L RUN/L ERR/SD/RD LED
Displays the CC-link communication status.
2)
Reset switch
Press after setting or changing the STATION, B RATE, VER.
3)
CC-Link communication connector
Connect the CC-link signal wire.
7)
IEC rail stopper
Used for fixing the IEC rail.
4)
STATION switch
Station setting switch: Set the CC-Link station number.
5)
B RATE switch
Baud rate setting switch.
Set the CC-Link transmission speed.
6)
VER. switch
Switch for changing the CC-Link version.
8)
Coupling tab
Used for fixing the CC-Link communication unit
to the energy measuring module.
Logging/Communication Unit
2
8
8
1
3
5
7
6
4
1
8
8
3
4
7
3
5
6
2
Front View
Left-side View
Backside View
Front View
Left-side View
Backside View
Connect the secondary output of the
dedicated current sensor connected to the
current wire of the measurement circuit.
Connect the secondary output of the
dedicated current sensor connected to the
current wire of the measurement circuit.
Connect with 485- terminal only if installed
at the first terminal (
→
Refer to p. 26 for the
MODBUS
®
RTU communication system
configuration).
Connect with 485- terminal only if installed
at the first terminal (
→
Refer to p. 26 for the
MODBUS
®
RTU communication system
configuration).