Product Lineup
Specifications
Examples of
EcoMonitorLight
Applications
External View
Names and
Functions of
Each Part
Connection
Configurations
/Wiring Precautions
Communication
Unit Wiring and
Setting Procedures
Energy measuring
devices
Model Name/
Specifications
Safety
Precautions
Device
Installation
Procedures
Features
Memo
Product Lineup
Specifications
Examples of EcoMonitorLight Applications
External View
Names and Functions of Each Part
Connection Configurations /Wiring Precautions
Communication Unit Wiring and Setting Procedures
Energy measuring devices
Model Name/ Specifications
Safety Precautions
Device Installation Procedures
Features
Memo
6
5
Broken lines indicate location
of misconnection.
This function displays items such as current and voltage
phase angles, and energy, current and voltage values for
each phase. By checking each displayed value, distinction
of whether there is a misconnection in current or voltage
input used for measuring is supported.
1.Features
Test Data
Output
Pulse/Alarm
Output
Receiving Devices
(Alarm lights, buzzers, etc.)
Host System
Example
of Misconnection
Examples of Display
Check Screens
*The above examples are sample images.
Refer to the operation manual for actual screens,
the check method, directions for use, etc.
*Refer to the operation manual for the table for distinction.
Operating time measurement
starts
Operating time measurement
ends
■High-Precision Measurement
■Operating Time Measurement
The current measurement time can be calculated in
seconds and the equipment operating time can be
displayed in hours (h) in order to utilize the data in
diagnosing production equipment service life and for
performing preventive maintenance.
*Operating time can also be output to the host system as CSV data.
Time [t]
Time[t]
Operated when
0.4% or more
of the rated
current is used.
Measure operating time
Power [kW]
Current [A]
It is possible for measurements to be missed when performing
continuous measurement of short-cycle loads because the power
used for spot or solder welding is used for an extremely short
period. The EcoMonitorLight provide high-precision measurement
so that the measurements of short-cycle loads are not missed.
You can specify contact inputs to the energy measuring unit (High
Performance Model only) as triggers for the start and end of
operating time in order to be able to measure operating time
according to actual equipment operation.
■Misconnection Support
■Test Function
This function enables communication of test data to the
host system without voltage or current input. By enabling
alarm and pulse test signal output, it becomes easy to
check wiring and perform system testing.
Measurement Functions
4
Support Functions
5
Power consumption value
increases momentarily during
spot or solder welding.
250μs
Advantage of High-Precision (Short-Cycle) Measurement
Operating Time Measurement with Specified Inputs as a Trigger
The continuous measurement of energy at sampling
cycles of approximately 250 μs allows for measuring
even short-cycle loads such as that for spot or solder
welding.
*Data of measured values, including power use as well as voltage, current and
similar items, is acquired at update cycles of 250 ms.
Devices correspond to the international standards of CE marking, UL
★
, and KC Marking,
and also meet the compliance demands for standards for embedded applications in overseas equipment.
*Please contact your nearest Mitsubishi Electric branch office or representative for information regarding the standards compliance status of each model.
★
Correspondence from production in February 2014.
(
Except for some models
)
Compliance with Foreign Standards
6
s
n
o
i
t
a
c
i
f
i
c
e
p
S
m
e
t
I
l
e
d
o
M
single-phase
2-wire
three-phase
3-wire
single-phase
3-wire
Nominal
System
Voltage
Measuring
circuit
three-phase
4-wire
Auxiliary power supply rating
100-240V AC (+10%, -15%),50Hz/60Hz, 10VA, Transient Overvoltage : 1,500V
T
A
C
:
t
i
u
c
r
i
c
g
n
i
r
u
s
a
e
M
e
g
a
t
l
o
v
r
e
v
O
t
n
e
i
s
n
a
r
T
Ⅲ
, Auxiliary power supply : CAT
Ⅱ
Possible combination current sensor
t
i
n
u
l
a
n
o
i
t
p
o
n
o
i
t
a
n
i
b
m
o
c
e
l
b
i
s
s
o
P
★
UL/c-UL is certified only for the following conditions.
※
1 EMU4-CM-C enables to transfer measured data to programmable controllers for data acquisition via CC-Link communication.
※
2 EMU4-LM enables to memorize the data of various quantities related to electricity for a certain period.
B
M
-
1
D
H
-
4
U
M
E
C
A
V
0
4
2
,
V
0
2
1
120V AC (b/w 1- and 2-side, 2- and 3-side),
240V AC (b/w 1- and 3-side)
C
A
V
0
2
1
/
Y
8
0
2
EMU-CT50/100/250,EMU2-CT5-4W
M
※2
L
-
4
U
M
E
C
※1
-
M
C
-
4
U
M
E
B
M
-
1
D
B
-
4
U
M
E
C
A
V
0
4
2
,
V
0
2
1
120V AC (b/w 1- and 2-side, 2- and 3-side),
240V AC (b/w 1- and 3-side)
t
n
a
il
p
m
o
c
-
n
o
N
M
※2
L
-
4
U
M
E
C
※1
-
M
C
-
4
U
M
E
EMU-CT50/100/250,EMU2-CT5
Summary of Contents for EMU4-BD1-MB
Page 9: ......