7.7 System Set Up
7.7.1 Main remote Controller Options
The heat pump unit comes factory fitted with a main remote controller. This incorporates a thermistor for temperature monitoring
and a graphical user interface to enable set-up, view current status and input scheduling functions. The main remote controller is
also used for servicing purposes. This facility is accessed via password protected service menus.
To provide the best efficiency Mitsubishi Electric recommends using automatic adaptation function based on room temperature.
To use this function a room thermistor needs to be present in a main living area. This can be done in a number of ways the most
convenient are detailed below.
Refer to heating section of this manual for instructions on how to set compensation curve, Flow temp. or Room temp.
(Auto adaptation).
For instructions on how to set the thermistor input for the FTC please refer to Initial settings section.
The factory setting for space heating mode is pre-set to Room temp. mode (auto adaptation). If there is no room sensor pre-
sent in the system, this setting must be changed to either Compensation curve mode or Flow temp. mode.
B-233