Outline view
Top view
How to use TBO.1 to 4
Note:
1. Do not connect multiple water circulation pumps directly to each output (OUT1, OUT2, and OUT3). In such a case,
connect them via (a) relay(s).
2. Do not connect water circulation pumps to both TBO.1 1-2 and CNP1 at the same time.
3. Connect an appropriate surge absorber to OUT10 (TBO.3 1-2) depending on the load at site.
4. Stranded wire should be processed with insulation-covered bar terminal (DIN46228-4 standard compatible type).
5. Use the same thing as the Signal input wire for OUTA1 wiring.
Item
Name
Model and specifications
External output
function
Outputs
wire
Use sheathed vinyl coated cord or cable.
Max. 30 m
Wire type: CV, CVS or equivalent
Wire size: Stranded wire: 0.25 mm² to 1.5 mm²
Solid wire: ø0.57 mm to ø1.2 mm
Wiring specification and local supply parts
Outputs
<Figure 7.4.6>
Connect them using either way as shown above.
Name Terminal
block
Connector Item
OFF ON
Signal/Max current Max. total
current
OUT1 TBO.1 1-2 CNP1
Water circulation pump 1 output (Space heating & DHW)
OFF ON
230V AC 0.6A Max.
3.0A
OUT2 TBO.1 3-4
—
Water circulation pump 2 output (Space heating for Zone1)
OFF ON
230V AC 1.0A Max.
OUT3 TBO.1 5-6
—
Water circulation pump 3 output (Space heating for Zone2) *1 OFF ON 230V AC 1.0A Max.
2-way valve 2b output *2
OUT14
—
CNP4
Water circulation pump 4 output (DHW)
OFF ON
230V AC 0.4A Max.
OUT4
—
CN851
3-way valve output
Heating DHW
—
1.3A
OUT5 TBO.2 1-2
—
Mixing valve output *1
Stop Close 230V AC 0.1A Max.
TBO.2 2-3
Open
OUT6
—
—
—
—
—
—
OUT7
—
—
—
—
—
—
OUT8 TBO.4 7-8
—
—
—
—
—
OUT9 TBO.4 5-6 CNIH
Immersion heater output
—
— 230V AC 0.1A Max.
(Relay)
OUT11 TBO.3 5-6
—
Error output
Normal Error 230V AC 0.5A Max.
OUT12 TBO.3 7-8
—
—
—
—
—
OUT13 TBO.4 3-4
—
2-way valve 2a output *2
OFF ON
230V AC 0.1A Max.
OUT15 TBO.4 1-2
—
Comp ON signal
OFF ON
230V AC 0.5A Max.
OUT10 TBO.3 1-2
—
Boiler output
OFF ON
non-voltage contact
·220-240V AC (30V
DC)
0.5A or less
·10mA 5V DC or
more
—
OUT16 TBO.3 3-4
—
Heating thermo ON signal
OFF ON
OUTA1 TBI.4 7-8
—
Analog output (PICV Output)
OFF ON
0-10V DC 5mA max.
—
Do not connect to the terminals that are indicated as “—” in the “Terminal block” field.
*1 For 2-zone temperature control.
*2 For 2-zone valve ON/OFF control.
B-216