6
Your Heating System
3
EN
Hydrobox
Model name
EHSD-
MEC
EHSD-
MC
EHSD- VM2C
EHSD-
YM9C
EHSC-
MEC
EHSC- VM2C
EHSC- VM2EC
EHSC- VM6C
EHSC- VM6EC
EHSC-
YM9C
EHSC-
YM9EC
EHSC-
TM9C
ERSD- VM2C
ERSC-
MEC
ERSC- VM2C
EHPX- VM2C
EHPX- VM6C
EHPX-
YM9C
Modes
Heating ONL
Y
Heating and Cooling
Heating ONL
Y
Overall unit dimensions
800×530×360 mm (Height×Width×Depth)
W
eight (empty)
38 kg
43 kg
44 kg
45 kg
42 kg
48 kg
43 kg
49 kg
44 kg
49 kg
44 kg
49 kg
45 kg
43 kg
49 kg
37 kg
38 kg
38 kg
W
eight (full)
44 kg
49 kg
50 kg
51 kg
49 kg
55 kg
50 kg
56 kg
51 kg
56 kg
51 kg
56 kg
51 kg
50 kg
56 kg
42 kg
43 kg
43 kg
Plate heat exchanger
—
—
—
Target temperature range
Flow temperature
Heating
25 - 60°C
Cooling
—
5 - 25°C
—
Room temperature
Heating
10 - 30°C
Cooling
—
NOT
available
—
Guaranteed operating range
Ambient *1
0 - 35°C (
80%RH)
Outdoor temperature
Heating
See outdoor unit spec table.
Cooling
—
See outdoor unit spec table
(min. 10°C).*2
—
Unvented expansion
vessel (Primary heating)
Nominal volume
—
10 L
—
10 L
—
10 L
—
10 L
—
10 L
—
10 L
Charge pressure
—
0.1 MPa (1 bar)
—
0.1 MPa (1 bar)
—
0.1 MPa (1 bar)
—
0.1 MPa (1 bar)
—
0.1 MPa (1 bar)
—
0.1 MPa (1 bar)
Electrical data
Control board
Power supply
(Phase, voltage, frequency)
~/N, 230V
, 50 Hz
Booster heater
Power supply
(Phase, voltage, frequency)
—
—
~/N, 230V
,
50Hz
3~, 400V
,
50Hz
—
~/N, 230V
,
50Hz
~/N, 230V
,
50Hz
~/N, 230V
,
50Hz
~/N, 230V
,
50Hz
3~, 400V
,
50Hz
3~, 400V
,
50Hz
3~, 230V
,
50Hz
~/N, 230V
,
50Hz
—
~/N, 230V
,
50Hz
~/N, 230V
,
50Hz
~/N, 230V
,
50Hz
3~, 400V
,
50Hz
Capacity
—
—
2kW
3kW + 6kW
—
2kW
2kW
2kW + 4kW
2kW + 4kW
3kW + 6kW
3kW + 6kW
3kW + 6kW
2kW
—
2kW
2kW
2kW + 4kW
3kW + 6kW
Current
—
—
9A
13A
—
9A
9A
26A
26A
13A
13A
23A
9A
—
9A
9A
26A
13A
*1
The environment must be frost-free.
*2
Cooling mode is not available in low outdoor temperature.
Product Specification (2/2)
Summary of Contents for ecodan EHPT20X-MHCW