![Mitsubishi Electric DX-TL2500E Installation And Operation Manual Download Page 95](http://html.mh-extra.com/html/mitsubishi-electric/dx-tl2500e/dx-tl2500e_installation-and-operation-manual_239363095.webp)
95
ENGLISH
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Specifications
Specifications
Rated Power Supply:
AC 100-240V 50/60Hz
Rated Input:
0.65 - 0.3A (100-240V)
Color System:
PAL type color system.
Operating Temperature:
41
°
F-104
°
F (5
°
C to 40
°
C).
Relative Humidity:
Max.80(%)
Altitude:
Max.2000(m)
Dimensions:
425(Width) x 375(Depth) x 118(Height)(mm).
Weight:
7.5kg
Recording System
Digital recording method using WAVELET compression.
Sampling
13.5MHz
Data Compression
WAVELET
Compression Unit
Field
Resolution
684 x 288
Recording Device
120GB HDD
Video Input:
16 Input BNC-Connector:
1.0 V(p-p), 75 ohms.
Monitor Output:
S-Connector:
Y-Signal: 1.0 V(p-p), 75 ohms.
C-Signal: 0.3 V(p-p), 75 ohms.
2 Output BNC-Connector:
1.0 V(p-p), 75 ohms.
RCA-Pinplug: 1.0 V(p-p), 75 ohms.
Throughout Output:
16 Output BNC-Connector:
1.0 V(p-p), 75 ohms.
Audio Input:
RCA-Pinplug: 308 mV(rms), 50 kohms.
Audio Output:
2 Output RCA-Pinplug: 308 mV(rms), 1 kohms.
Microphone Input:
Ø
3.5mm stereo minijack: 0.346 mV(rms), 600 ohms.
Timer Program:
8 programs-Daily start and stop time for one week x 3set.
Memory Backup:
Lasts for more than 1 month.
CONNECTORS
ALARM IN(1-16) Input:
Terminal for starting alarm recording.
CLOCK ADJ Input:
Terminal for adjusting clock.
REC Input:
Terminal for start recording.
EMERGENCY Input:
Terminal for start emergency recording.
GND:
Terminal for ground.
MODE OUT(1-5) Output:
Terminal for indication of recording selected mode.
DC 5V OUT Output:
Terminal for DC 5V OUT. Max. Drive current 30mA DC.
CALL OUT/CALL OUT GND:
Terminal for external warning device.
RS-485/RS-422 Terminal for operations of pan, tilt and zoom of a dome camera.
Rating:
MODE OUT(1-5)
Active:
“Low” Level.
Max. Drive current 7mA DC.
Non active:
Open.
Max. V24V DC.
ALARM IN / CLOCK ADJ /
Active:
When terminals are short-circuited
REC/EMERGENCY
or “Low” Level voltage is applied.
Non active:
Open.
CALL OUT /
Active:
ON.
Max. Drive current 7mA DC.
CALL OUT GND
Non active:
Open.
Max. V24V DC.
RS-232C
RS-232C (D-SUB 9pin) connector for connection with personal computer.
SCSI SCSI2 (Half pitch 50 pin ) connector.
ETHERNET Connector form: RJ-45
Physical interface: 10BASE-T
Accessories
AC power cord (for U.K / for the Continent)
2
COMPACT FLASH slot cover (mounted on unit)
1
Compact Flash Card recording format
Original format (FSM2)
CD-R/RW recording format
Original format (FSM2)
Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.