45
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
ENGLISH
■
ALARM REC DURATION
The recording time during alarm recording can be set.
<RECORD SETTINGS>
ALARM SETTING
RECORD SETTING
>>ALARM REC DURATION 5S
MOTION DET REC ALARM
ARCHIVE OVERWRITE OFF
ARCHIVE MEDIA AUTO EJECT OFF
Setting ( default : “5S” )
“2S”, “5S”, “10S”, “15S”, “30S”, “45S”, “1M”, “2M”,
“5M”, “10M”, “20M”, “30M”, “60M”, “MANUAL”
“MANUAL” : Alarm recording is continued until the
grounding of the ALARM IN terminals is cancelled.
1. Press the SET UP button
}
<SETTINGS>
}
Select “ALARM
REC DURATION” in the <RECORD SETTINGS> screen.
Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
■
MOTION DET REC
Select whether alarm recording or normal recording is to
be started when motion is detected.
<RECORD SETTINGS>
ALARM SETTING
RECORD SETTING
ALARM REC DURATION 5S
>>MOTION DET REC ALARM
ARCHIVE OVERWRITE OFF
ARCHIVE MEDIA AUTO EJECT OFF
Setting ( default : “ALARM” )
“ALARM” : Alarm recording is started when the mo-
tion is detected.
“NORMAL” : Normal recording is started when the
motion is detected.
Recording is done with the recording interval and
the quality set by “A-PPS” and “A-GRADE”, inde-
pendent of whether “ALARM” or “NORMAL” has
been selected.
1. Press the SET UP button
}
<SETTINGS>
}
Select
“MOTION DET REC” in the <RECORD SETTINGS> screen,
and display the desired setting.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
■
ARCHIVE OVERWRITE
When backing-up data with an ARCHIVE device, the unit
can be set to start overwriting from the beginning.
<RECORD SETTINGS>
ALARM SETTING
RECORD SETTING
ALARM REC DURATION 5S
MOTION DET REC ALARM
>>ARCHIVE OVERWRITE OFF
ARCHIVE MEDIA AUTO EJECT OFF
This setting is displayed when “ARCHIVE•COPY”
is selected on “ID4•ID5” on the <INITIALIZATION>
screen.
ARCHIVE OVERWRITE commences back up
after all data on the ARCHIVE device is deleted.
This setting does not function during Timer re-
cording. Select “OVER” or “OVER-E” in the <TIMER
PROGRAM> screen to perform archive in Timer re-
cording mode.
Setting ( default : “OFF” )
“OFF” : Do not overwrite data when start archive.
“ON” : Overwrite data when start archive.
1. Press the SET UP button
}
<SETTINGS>
}
Select
“ARCHIVE OVERWRITE” in the <RECORD SETTINGS>
screen, and display the desired setting.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
■
ARCHIVE MEDIA AUTO EJECT
Automatic media ejection after completion of archive can
be set.
<RECORD SETTINGS>
ALARM SETTING
RECORD SETTING
ALARM REC DURATION 5S
MOTION DET REC ALARM
ARCHIVE OVERWRITE OFF
>>ARCHIVE MEDIA AUTO EJECT OFF
When stops archive during backing-up the unit
ejects the ARCHIVE media automatically.
This setting is displayed when “ARCHIVE•
COPY” is selected on “ID4•ID5” on the <INITIALI-
ZATION> screen.
This setting does not function during Timer re-
cording. Select “OVER-E” or “CONT-E” in the
<TIMER PROGRAM> screen to perform ARCHIVE
MEDIA AUTO EJECT in Timer recording mode.
Setting ( default : “OFF” )
“OFF” : Do not automatically eject media after com-
pletion of archive.
“ON” : Automatically eject media after completion
of archive.
1. Press the SET UP button
}
<SETTINGS>
}
Select
“ARCHIVE MEDIA AUTO EJECT” in the <RECORD
SETTINGS> screen, and display the desired setting.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.