D700 QUICK START MANUAL
10
Parameter
Name
Setting
Range
Initial Value
557
Current average value monitor
signal output reference current
0 to 500A
Rated inverter
current
561
PTC thermistor protection level
0.5 to 30kΩ,
9999
9999
563
Energization time carrying over
times
(0 to 65535)
0
564
Operating time carrying-over times
(0 to 65535)
0
571
Holding time at a start
0 to 10s, 9999
9999
575
Output interruption detection time
0 to 3600s,
9999
1s
576
Output interruption detection level
0 to 400Hz
0Hz
577
Output interruption cancel level
900 to 1100%
1000%
611
Acceleration time at a restart
0 to 3600s,
9999
9999
653
Speed smoothing control
0 to 200%
0
665
Regeneration avoidance frequency
gain
0 to 200%
100
872 *6
Input phase loss protection
selection
0, 1
0
882
Regeneration avoidance operation
selection
0, 1, 2
0
883
Regeneration avoidance operation
level
300 to 800V
400VDC/
780VDC *5
885
Regeneration avoidance
compensation frequency limit value 0 to 10Hz, 9999 6Hz
886
Regeneration avoidance voltage
gain
0 to 200%
100%
888
Free parameter 1
0 to 9999
9999
889
Free parameter 2
0 to 9999
9999
891
Cumulative power monitor digit
shifted times
0 to 4, 9999
9999
C1 (901) *4 AM terminal calibration
-
-
C2 (902) *4 Terminal 2 frequency setting bias
frequency
0 to 400Hz
0Hz
C2 (902) *4 Terminal 2 frequency setting bias
0 to 300%
0%
C3 (902) *4 Terminal 2 frequency setting gain
bias
0 to 400Hz
60Hz
125 (903)
*4
Terminal 2 frequency setting gain
frequency
0 to 300%
60Hz
C4 (903) *4 Terminal 2 frequency setting gain
0 to 300%
100%
C5 (904) *4 Terminal 4 frequency setting bias
frequency
0 to 400Hz
0Hz
C6 (904) *4 Terminal 4 frequency setting bias
0 to 300%
20%
126 (905)
*4
Terminal 4 frequency setting gain
frequency
0 to 400Hz
60Hz
C7 (905) *4 Terminal 4 frequency setting gain
0 to 300%
100%
C22 (922)
*4
Parameter for manufacturer setting. Do not set.
C23 (922)
*4
C24 (923)
*4
C25 (923)
*4
990
PU buzzer control
0, 1
1
991
PU contrast adjustment
0 to 63
58
Pr.CL
Parameter clear
0, 1
0
ALLC
All parameter clear
0, 1
0
Er.CL
Faults history clear
0, 1
0
Pr.CH
Initial value change list
-
-
1. Differ according to capacities.
6%: FR-D720-042 or less, FR-D740-022 or less, FR-D720S-042 or less
4%: FR-D720-070 to 165, FR-D740-036 to 080, FR-D720S-070 and 100
3%: FR-D720-238 and 318, FR-D740-120 and 160
2. Differ according to capacities.
5s: FR-D720-165 or less, FR-D740-080 or less, FR-D720S-008 to 100
10s: FR-D720-238 and 318, FR-D740-120 and 160
3. Differ according to capacities.
6%: FR-D720-008 and 014, FR-D720S-008 and 014
4%: FR-D720-025 to 318, FR-D740-012 to 160, FR-D720S-025 to 100
4. The parameter number in parentheses is the one for use with the operation
panel (FR-PA02-02) for the FR-E500 series or parameter unit (FR-PU04/ FR-
PU07).
5. The initial value differs according to the voltage class. (200V class, 400V class)
6. Available only for the three-phase power input specification model.
8. OPERATION PANEL
The operation panel cannot be removed from the inverter.
Operation mode indication
EXT: Lit to indicate External operation mode.
(Lit at power-ON at initial setting.)
NET: Lit to indicate Network operation mode.
PU, EXT: Lit to indicate External/PU
combined operation mode 1, 2.
These turn OFF when command source is
not on operation panel
Unit indication
Hz: Lit to indicate frequency.
(Flickers when the set frequency
monitor is displayed.)
A: Lit to indicate current.
(Both "Hz" and "A" turn off when other
than the above is displayed.)
Monitor (4-digit LED)
Shows the frequency, parameter number,
etc.
Setting dial
(Setting dial: Mitsubishi inverter dial)
Used to change the frequency setting
and parameter values.
Press to display the following.
Displays the set frequency in the
monitor mode
Present set value is displayed during
calibration
Displays the order in the faults history
mode
Mode switchover
Used to change each setting mode.
Pressing
simultaneously changes
the operation mode.
Pressing for a while (2s) can lock
operation.
Determination of each setting
If pressed during operation, monitor
changes as below;
Running frequency
Output current
Output voltage
Operating status indication
Lit or flicker during inverter operation.
* On:Indicates that forward rotation
operation is being performed.
Slow flickering (1.4s cycle):
Reverse rotation operation
Fast flickering (0.2s cycle):
When
was pressed or the
start command was given, but the
operation can not be made.
than the starting frequency.
When the MRS signal is input.
Parameter setting mode indication
Lit to indicate parameter setting mode.
Monitor indication
Lit to indicate monitoring mode.
Stop operation
Used to stop Run command.
Fault can be reset when protective
function is activated (fault).
Operation mode switchover
Used to switch between the PU and
External operation mode.
When using the External operation mode
(operation using a separately connected
frequency setting potentiometer and start
signal), press this key to light up the EXT
indication.
(Press
simultaneously (0.5s)
change
Pr. 79
setting to change
to combined mode .)
PU: PU operation mode
EXT: External operation mode
Cancels PU stop also.
Start command
The rotation direction can be selected by
setting
Pr. 40
.
When the frequency command is less
PU: Lit to indicate PU operation mode.
MitsubishiElectric Automation, Inc.